hpialarms(1) OpenHPI hpialarms(1)NAMEhpialarms - A openhpi sample application that shows "Alarm Control"
management instruments
SYNOPSIShpialarms [-D id] [-N host[:port]] [-C <cfgfile>]
[-a 1|0][-b 1|0][-c 1|0][-m 1|0][-n 1|0][-p 1|0][-i n][-o][-X][-h]
hpialarms [--domain=id] [--host=host[:port]] [--cfgfile=file]
[--diska=1|0] [--diskb=1|0] [--critical=1|0] [--major=1|0]
[--minor=1|0] [--power=1|0] [--chassisid=n] [--all] [--debug] [--help]
DESCRIPTIONhpialarms walks the RPT (Resource Presence Table) for resources that
have "Alarm Control" management instruments (SAHPI_CTRL_LED).
If no domain or host is selected, hpialarms uses the default domain as
specified in the openhpiclient.conf file.
OPTIONS
(No Option) Display alarm states
Help Options:
-h, --help
Show help options
Application Options:
-c 1|0, --critical=1|0
Set critical alarm on|off
-m 1|0, --major=1|0
Set major alarm on|off
-n 1|0, --minor=1|0
Set minor alarm on|off
-a 1|0, --diska=1|0
Set diska alarm on|off
-b 1|0, --diskb=1|0
Set diskb alarm on|off
-p 1|0, --power=1|0
Set power alarm on|off
-i n, --chassisid=n
Set chassis id on for n seconds
-o, --all
Set all alarms off
-D nn, --domain=nn
Select domain id nn
-X, --debug
Display debug messages
-N "host[:port]", --host="host[:port]"
Open session to the domain served by the daemon at the specified URL
(host:port). This option overrides the OPENHPI_DAEMON_HOST and
OPENHPI_DAEMON_PORT environment variables. If host contains ':' (for
example IPv6 address) then enclose it in square brackets. For
example: "[::1]" or "[::1]:4743".
-C "file", --cfgfile="file"
Use passed file as client configuration file. This option overrides
the OPENHPICLIENT_CONf environment variable.
SAMPLE OUTPUT
hpialarmpanel ver 0.6
RptInfo: UpdateCount = 5, UpdateTime = 8a2dc6c0
rptentry[0] resourceid=1 tag: Mullins
RDR[45]: ctltype=2:1 oem=0 Chassis Identify Control
RDR[48]: ctltype=0:1 oem=10 Front Panel Power Alarm LED state = off
RDR[51]: ctltype=0:1 oem=13 Front Panel Minor Alarm LED state = ON
RDR[46]: ctltype=0:0 oem=0 Cold Reset Control
RDR[49]: ctltype=0:1 oem=11 Front Panel Critical Alarm LED state = off
RDR[50]: ctltype=0:1 oem=12 Front Panel Major Alarm LED state = off
SEE ALSO
hpi_shell
hpidomain hpigensimdata hpireset hpitop
hpiel hpiinv hpisensor hpitree
hpievents hpionIBMblade hpisettime hpiwdt
hpifan hpipower hpithres hpixml
ohdomainlist ohhandler ohparam
AUTHORS
Authors of this man page:
Peter D Phan (pdphan@users.sourceforge.net)
Ulrich Kleber (ulikleber@users.sourceforge.net)
Anton Pak (avpak@users.sourceforge.net)
3.2.1 2011-09-20 hpialarms(1)