SMINFO(8) Open IB Diagnostics SMINFO(8)NAME
SMINFO -
query InfiniBand SMInfo attribute
SYNOPSIS
sminfo [options] sm_lid | sm_dr_path [modifier]
DESCRIPTION
Optionally set and display the output of a sminfo query in human read‐
able format. The target SM is the one listed in the local port info, or
the SM specified by the optional SM lid or by the SM direct routed
path.
Note: using sminfo for any purposes other then simple query may be very
dangerous, and may result in a malfunction of the target SM.
OPTIONS
-s, --state <state> set SM state
0 not active
1 discovering
2 standby
3 master
-p, --priority <priority> set priority (0-15)
-a, --activity <val> set activity count
Addressing Flags
-D, --Direct The address specified is a directed route
Examples:
[options] -D [options] "0" # self port
[options] -D [options] "0,1,2,1,4" # out via port 1, then 2, ...
(Note the second number in the path specified must match the port being
used. This can be specified using the port selection flag '-P' or the
port found through the automatic selection process.)
-G, --Guid The address specified is a Port GUID
-L, --Lid The address specified is a LID
Port Selection flags
-C, --Ca <ca_name> use the specified ca_name.
-P, --Port <ca_port> use the specified ca_port.
Local port Selection
Multiple port/Multiple CA support: when no IB device or port is speci‐
fied (see the "local umad parameters" below), the libibumad library
selects the port to use by the following criteria:
1. the first port that is ACTIVE.
2. if not found, the first port that is UP (physical link up).
If a port and/or CA name is specified, the libibumad library
attempts to fulfill the user request, and will fail if it is not
possible.
For example:
ibaddr # use the first port (criteria #1 above)
ibaddr -C mthca1 # pick the best port from "mthca1" only.
ibaddr -P 2 # use the second (active/up) port from the first available IB device.
ibaddr -C mthca0 -P 2 # use the specified port only.
Debugging flags
-d raise the IB debugging level. May be used several times (-ddd
or -d -d -d).
-e show send and receive errors (timeouts and others)
-h, --help show the usage message
-v, --verbose
increase the application verbosity level. May be used several
times (-vv or -v -v -v)
-V, --version show the version info.
Configuration flags
-t, --timeout <timeout_ms> override the default timeout for the
solicited mads.
-y, --m_key <key>
use the specified M_key for requests. If non-numeric value (like
'x') is specified then a value will be prompted for.
--config, -z <config_file> Specify alternate config file.
Default: /etc/infiniband-diags/ibdiag.conf
FILES
CONFIG FILE
/etc/infiniband-diags/ibdiag.conf
A global config file is provided to set some of the common options for
all tools. See supplied config file for details.
EXAMPLES
:: sminfo # local port's sminfo sminfo 32
# show sminfo of lid 32 sminfo-G 0x8f1040023 # same but using
guid address
SEE ALSO
smpdump (8)
AUTHOR
Hal Rosenstock
< halr@voltaire.com >
SMINFO(8)