RARC(1)RARC(1)NAMErarc - ra client resource file.
SYNOPSISrarcCOPYRIGHT
Copyright (c) 2000-2008 QoSient. All rights reserved.
DESCRIPTION
Ra* clients will open this file if its in the users $HOME directory, or
in the $ARGUSHOME directory, and parse it to set common configuration
options. All of these values will be overriden by options set on the
command line, or in the file specified using the '-F conffile' option.
Values can be quoted to make string denotation easier, however, the
parser does not require that string values be quoted. To support this,
the parse will remove " (double quote) characters from input strings,
so do not use this character in strings themselves.
Values specified as "" will be treated as a NULL string, and the parser
will ignore the variable setting.
RA_ARGUS_SERVER
All ra* clients can attach to a remote server, and collect argus data
in real time. This variable can be a name or a dot notation IP
address. Optionally you can specify a port number using a ':' and then
providing the port number desired.
RA_ARGUS_SERVER=localhost:561
RA_CISCONETFLOW_PORT
All ra* clients can read Cisco Netflow records directly from Cisco
routers. Specifying this value will alert the ra* client to open a UDP
based socket listening for Cisco Netflow data on the port number speci‐
fied.
RA_CISCONETFLOW_PORT=
RA_OUTPUT_FILE
All ra* clients can support writing output as Argus Records into a file
or stdout. Stdout is specified as '-'.
RA_OUTPUT_FILE="filename"
RA_TIMERANGE
All ra* clients can support input filtering on a time range. The format
is:
timeSpecification[-timeSpecification]
where the format of a timeSpecification can be:
[[[yy/]mm/]dd.]hh[:mm[:ss]]
[yy/]mm/dd
RA_TIMERANGE="55/12/04.00:00:01-55/12/04.23:59:59"
RA_TIMERANGE="12/04-12/05"
RA_RUN_TIME
All ra* clients can support running for a number of seconds, while
attached to a remote source of argus data. This is a type of polling.
The default is zero (0), which means run indefinately.
RA_RUN_TIME=0
RA_PRINT_LABELS
Most ra* clients are designed to print argus records out in ASCII, with
each client supporting its own output formats. For ra() like clients,
this variable will generate column headers as labels. The number is
the number of lines between repeated header labeling. Setting this
value to zero (0) will cause the labels to be printed once. If you
don't want labels, comment this line out, delete it or set the value
to -1.
RA_PRINT_LABELS=0
RA_FIELD_DELIMITER
Most ra* clients are designed to print argus records out in ASCII, with
each client supporting its own output formats. For ra() like clients,
this variable can overide the default field delimiter, which are vari‐
able spans of space (' '), to be any character. The most common are
expected to be '' for tabs, and ',' for comma separated fields.
RA_FIELD_DELIMITER=','
RA_PRINT_NAMES
For ra(1) like clients, this variable will control the translation of
various numbers to names, such as address hostnames, port service names
and/or protocol names. There can be a huge performance impact with
name lookup, so the default is to not resolve hostnames.
RA_PRINT_NAMES=port
Other valid options are none to print no names, proto to translate the
protocol names, port to translate port names, and all to translate all
the fields. An invalid option will default to port, silently.
RA_PRINT_RESPONSE_DATA
For ra() like clients, this variable will include the response data
that is provided by Argus. This is protocol and state specific.
RA_PRINT_RESPONSE_DATA=no
RA_PRINT_UNIX_TIME
For ra() like clients, this variable will force the timestamp to be in
Unix time format, which is an integer representing the number of
elapsed seconds since the epoch.
RA_PRINT_UNIX_TIME=no
RA_TIME_FORMAT
For ra() like clients, the format that is used to print timestamps, is
based on the strftime() library call, with an extension to print frac‐
tions of a sec using "%f". The default is "%T.%f". You can overide
this default time format by setting this variable. This string must
conform to the format specified in strftime(). Malformed strings can
generate interesting output, so be aware with this one, and don't for‐
get the '.' when doing fractions of a second.
RA_TIME_FORMAT="%T.%f"
RA_TZ
The timezone used for timestamps is specified by the tzset() library
routines, and is normally specified by factors such as the TZ environ‐
ment variable found on most machines. You can override the TZ environ‐
ment variable by specifying a time zone using this variable. The for‐
mat of this string must conform to the format specified by tzset(3).
RA_TZ="EST5EDT4,M3.2.0/02,M11.1.0/02"
RA_TZ="PST8PDT"
RA_USEC_PRECISION
For ra() like clients, this variable is used to override the time for‐
mat of the timestamp. This variable specifies the number of decimal
places that will be printed as the fractional part of the time. Argus
collects usec precision, and so a maximum value of 6 is supported. To
not print the fractional part, specify the value zero (0).
RA_USEC_PRECISION=6
RA_USERDATA_ENCODE
Argus can capture user data. When printing out the user data contents,
using tools such as raxml(), the type of encoding can be specified
here. Supported values are "Ascii", or "Encode64".
RA_USERDATA_ENCODE=Ascii
RA_DEBUG_LEVEL
If compiled to support this option, ra* clients are capable of generat‐
ing a lot of use [full | less | whatever] debug information. The
default value is zero (0).
RA_DEBUG_LEVEL=0
RA_FILTER
You can provide a filter expression here, if you like. It should be
limited to 2K in length. The default is to not filter. See ra(1) for
the format of the filter expression.
RA_FILTER=""
SASL SUPPPORT
When argus is compiled with SASL support, ra* clients may be required
to authenticate to the argus server before the argus will accept the
connection. This variable will allow one to set the user and autho‐
rization id's, if needed. Although not the best practice, you can pro‐
vide a password through the RA_AUTH_PASS variable. If you do this, you
should protect the contents of this file. The format for this variable
is:
RA_USER_AUTH="user_id/authorization_id"
RA_AUTH_PASS="password"
The clients can specify a part of the negotiation of the security pol‐
icy that argus uses. This is controlled through the use of a minimum
and maximum allowable protection strength values. Set these variable
to control this policy.
RA_MIN_SSF=0
RA_MAX_SSF=128
If compiled to support this option, ra* clients are capable of generat‐
ing a lot of use [full | less | whatever] debug information. The
default value is zero (0).
RA_DEBUG_LEVEL=0
Some ra style clients use a non-blocking method to connect to remote
data sources, so the user many need to control how long to wait if a
remote source doesn't respond. This variable sets the number of sec‐
onds to wait. This number should be set to a reasonable value (5 <
value < 60). The default value is 10 seconds.
RA_CONNECT_TIME=10
Some ra* clients have an interval based function. Ratop, as an exam‐
ple, can refresh the screen at a fixed interval. This variable can be
set using the RA_UPDATE_INTERVAL variable, which is a float in seconds.
0.5 seconds is the default.
RA_UPDATE_INTERVAL=0.5
All ra* clients have the ability to print country codes for the IP
addresses that are in a flow record. Country codes are generated from
the ARIN delegated address space files. Specify the location of your
DELEGATED_IP file here.
No Commandline equivalent
RA_DELEGATED_IP="/usr/local/argus/delegated-ipv4-latest"
SEE ALSOra(1)
07 November 2000 RARC(1)