DS2755(3)		     One-Wire File System		     DS2755(3)

NAME
       DS2755, DS2756 - Multichemistry Battery Fuel Gauge

SYNOPSIS
   Temperature Voltage, Current, Memory, and Switch.
       35 [.]XXXXXXXXXXXX[XX][/[ alarm_set/[volthigh|voltlow|temphigh|templow]
       | lock.[0-2|ALL] | memory | pages/page.[0-2|ALL] | PIO | sensed |  tem‐
       perature | vbias | vis | volt | volthours |
       defaultpmod  |  pie0  |	pie1 | rnaop | ios | uben | ovd | pmod | por |
       uven |
       ]]

   Thermocouple
       35   [.]XXXXXXXXXXXX[XX][/[    temperature    |	  typeX/range_low    |
       typeX/range_high | typeX/temperature

FAMILY CODE
       35

SPECIAL PROPERTIES
   alarm_set/templow alarm_set/temphigh
       read-write, integer
       High and low alarm settings for temperature

   alarm_set/voltlow alarm_set/volthigh
       read-write, floating point
       High and low alarm settings for volts

   lock.[0-2|ALL]
       read-write, yes-no
       Lock any of the three eprom pages to prevent further writes. Apparently
       setting lock is permanent.

   memory
       read-write, binary
       Access to the full 256  byte  memory  range.  Much  of  this  space  is
       reserved or special use. User space is the page area.
       See the DATASHEET for a full memory map.

   pages/pages.[0-2|ALL]
       read-write,  binary Three 32 byte areas of memory for user application.
       The lock property can prevent further alteration.
       NOTE that the page property is different from the common OWFS implemen‐
       tation in that all of memory is not accessible.

   PIO
       write-only, yes-no
       Controls the PIO pin allowing external switching.
       Writing	"1"  turns  the PIO pin on (conducting). Writing "0" makes the
       pin non-conducting.  The logical state of the voltage can be read  with
       the  sensed property. This will reflect the current voltage at the pin,
       not the value sent to PIO
       Note also that PIO will also be altered	by  the	 power-status  of  the
       DS2670 See the datasheet for details.

   sensed
       read-only, yes-no
       The  logical voltage at the PIO pin. Useful only if the PIO property is
       set to "0" (non-conducting).
       Value will be 0 or 1 depending on the voltage threshold.

   temperature
       read-only, floating point
       Temperature read by the chip at high resolution (~13 bits).  Units  are
       selected	 from the invoking command line. See owfs(1) or owhttpd(1) for
       choices. Default is Celsius.
       Conversion is continuous.

   vbias
       read-write, floating point
       Fixed offset applied to each vis measurement. Used  for	the  volthours
       value. Units are in Volts.
       Range -2.0mV to 2.0mV

   vis
       read-only, floating point
       Current	sensor reading (unknown external resistor). Measures the volt‐
       age gradient between the Vis pins. Units are in Volts
       The vis readings are integrated over  time  to  provide	the  volthours
       property.
       The  current  reading is derived from vis assuming the internal 25 mOhm
       resistor is employed. There is no way to know this through software.

   volt
       read-only, floating point
       Voltage read at the voltage sensor;. This  is  separate	from  the  vis
       voltage that is used for current measurement. Units are Volts
       Range is between 0 and 4.75V

   volthours
       read-write, floating point
       Integral of vis - vbias over time. Units are in volthours

THERMOCOUPLE
   typeX/
       directory
       Thermocouple  circuit  using the DS2755 to read the Seebeck voltage and
       the reference temperature. Since the type interpretation of the	values
       read depends on the type of thermocouple, the correct directory must be
       chosen. Supported thermocouple types include types B, E, J, K, N, R,  S
       and T.

   typeX/range_low typeX/ranges_high
       read-only, flaoting point
       The  lower  and	upper  temperature  supported by this thermocouple (at
       least by the conversion routines). In the globally  chosen  temperature
       units.

   typeX/temperature
       read-only, floating point
       Thermocouple  temperature.  Requires  a voltage and temperature conver‐
       sion. Returned in globally chosen temperature units.
       Note: there are two types of  temperature  measurements	possible.  The
       temperature value in the main device directory is the reference temper‐
       ature read at the chip. The typeX/temperature value is at  the  thermo‐
       couple junction, probably remote from the chip.

OBSCURE PROPERTIES
   pmod por uven pie0 pie1 ios uben ovd rnaop
       varies, yes-no
       Bit  flags corresponding to various battery management functions of the
       chip. See the DATASHEET for details of the identically named entries.
       In general, writing "0" corresponds to a 0 bit value, and non-zero cor‐
       responds to a 1 bit value.

   defaultpmod
       read-write, yes-no
       Default power-on state for the corresponding properties.

STANDARD PROPERTIES
ALARMS
       Temperature and voltage.

DESCRIPTION
   DS2755 DS2756
       The  DS2755 (3) and DS2756 (3) are battery charging controllers similar
       to the DS2751 (3) except no internal resistor option and a larger  EEP‐
       ROM memory.

       The DS2756 (3) adds suspend modes ( pie0 pie1 ) to the DS2755 (3)

       A  number  of  interesting devices can be built with the DS2755 (3) and
       DS2756 (3) including thermocouples. Support for thermocouples in	 built
       into  the  software, using the embedded thermister as the cold junction
       temperature.

ADDRESSING
DATASHEET
       http://pdfserv.maxim-ic.com/en/ds/DS2755.pdf
       http://pdfserv.maxim-ic.com/en/ds/DS2756.pdf

SEE ALSO
AVAILABILITY
       http://www.owfs.org

AUTHOR
       Paul Alfille (paul.alfille@gmail.com)

OWFS Manpage			     2003			     DS2755(3)
[top]

List of man pages available for DragonFly

Copyright (c) for man pages and the logo by the respective OS vendor.

For those who want to learn more, the polarhome community provides shell access and support.

[legal] [privacy] [GNU] [policy] [cookies] [netiquette] [sponsors] [FAQ]
Tweet
Polarhome, production since 1999.
Member of Polarhome portal.
Based on Fawad Halim's script.
....................................................................
Vote for polarhome
Free Shell Accounts :: the biggest list on the net