HobbyBoards_EE/EF(3)	     One-Wire File System	  HobbyBoards_EE/EF(3)

NAME
       - HobbyBoards EE/EF Microprocessor-based slaves:
	      Ultra  Violet (UV) Index sensor, Soil and Leaf moisture measure‐
	      ments, Barometer, 4-channel hub with switchable branches

SYNOPSIS
   General EE device
       EE [.]XXXXXXXXXXXX[XX][/[ temperature | version | type_number | temper‐
       ature_offset | ]]

   UVI sensor
       EE  [.]XXXXXXXXXXXX[XX][/[  UVI/UVI  |  UVI/UVI_offset  | UVI/in_case |
       UVI/valid | temperature | version | type_number | temperature_offset ]]

   General EF device
       EF [.]XXXXXXXXXXXX[XX][/[ version | type_number | ]]

   Moisture Meter
       moisture/sensor.[0-3|ALL]
       moisture/is_moisture.[0-3|ALL|BYTE] | moisture/is_leaf.[0-3|ALL|BYTE]
       moisture/calibrate/min  |   moisture/calibrate/max   |	moisture/cali‐
       brate/raw.[0-4|ALL]

   Hub
       hub/branch.[0-3|ALL|BYTE] | hub/short.[0-3|ALL|BYTE]

FAMILY CODE
       EE     Device with temperature

       EE     UVI

       EF     Device without temperature

       EF     Moisture Meter

       EF     Hub

TEMPERATURE PROPERTIES
   temperature
       read-only, floating point
       Temperature  read  every	 30  seconds. Resolution .5C (uses an on-board
       DS18B20). Temperature is only present in the EE-series devices.

   temperature_offset
       read-write, floating point
       Offset stored on device to apply to temperature readings.

UVI PROPERTIES
   UVI/UVI
       read-only floating point
       UV Index (ultraviolet index) in the range 0.0 to 16.0 resolution .1

       Only the UVI version of the EE device has a UVI sensor.	Readings  made
       every .5 seconds.

   UVI/UVI_offset
       read-write, floating point
       Signed  offset  to  apply to the UVI measurement. Stored on-device non-
       volatile.

   UVI/in_case
       read-write, yes-no
       Flag to apply compensation for the protective  case.  Stored  on-device
       non-volatile.

   UVI/valid
       read-only,  yes-no  Flag	 the  the EE device type matches the known UVI
       type.

Moisture Meter
   moisture/sensor.0 .. moisture/sensor.3 moisture/sensor.ALL
       read-only integer
       Up to 4 sensors reading moisture can be attached.  OWFS	addresses  the
       sensors	as  0  through	3  while the datasheet uses 1-4.  Two types of
       external sensors are supported (and the data range):

       Watermark Soil Moisture Sensor
	      0-199

       Leaf Wetness Sensor
	      0-99

   moisture/is_moisture.0 .. moisture/is_moisture.3 moisture/is_moisture.ALL
   moisture/is_leaf.0 .. moisture/is_leaf.3 moisture/is_leaf.ALL
       read-write yes_no
       Set or get the type of sensor attached to each channel. Note that  OWFS
       addresses the sensors as 0 through 3 while the datasheet uses 1-4.  Two
       types of external sensors are supported:

       Watermark Soil Moisture
	      Sensor

       Leaf Wetness
	      Sensor

       Note that is_leaf and is_moisture are complementary  and	 clearing  one
       sets the other.

   moisture/calibrate/min
   moisture/calibrate/max
       read-write unsigned integer
       Set  or get the upper and lower range for the raw data for leaf wetness
       scaling. See the datasheet for details.

   moisture/calibrate/raw.0   ..    moisture/calibrate/raw.3	moisture/cali‐
       brate/raw.ALL
       read-only unsigned integer
       Read the raw leaf wetness values for setting scaling. See the datasheet
       for details.  Note that OWFS addresses the sensors as 0 through 3 while
       the datasheet uses 1-4.

Hub
       4-channel hub. Individual branches can be switched on and off.

   hub/branch.0 .. hub/branch.3 hub/branch.ALL hub/branch.BYTE
       read-write, yes-no
       The  HobbyBoards hub has four 1-wire bus lines. Each branch is electri‐
       caly isolated from  reflections	and  shorts,  and  can	be  optionally
       excluded from the 1-wire network.

       You  can turn each branch on or off by writing 0 (off) or 1 (on) to the
       corresponding property. Note that OWFS indexes  the  branches  0	 to  3
       while the datasheet uses 1 to 4.

       The  easiest  way  to turn all the branches on is to write 15 (0x0F) to
       hub/branch.BYTE

   hub/short.0 .. hub/short.3 hub/short.ALL hub/short.BYTE
       read-only, yes-no
       Is the corresponding branch in "short" condition? (Electrically shorted
       out).

IDENTIFICATION PROPERTIES
   version
       read-only, ascii
       Firmware	 version  for the EE/EF device. Reported in nn.nn format where
       nn is major/minor decimal value.

       Note: This format was changed as of version owfs-2.9p6 at  the  request
       of the HobbyBoards. Formerly reported in HH.HH format where HH is a hex
       digit (0-9A-F).

   type_number
       read-only, integer
       Index of the type of sensor  built  into	 this  device.	Current	 known
       assignments:

       1      UVI (Ultraviolet index)

       2      Moisture meter

       3      Moisture meter with datalogger

       4      Sniffer

       5      Hub

STANDARD PROPERTIES
ALARMS
       None

DESCRIPTION
   EE / EF
       The  EEEF  (3)  are a reference platform of microprocessor based 1-wire
       slaves. In general they require external power, and  have  an  on-board
       index  for the specific capabilities. They are designed by Eric Vickery
       at HobbyBoards.com

       The EE class device uses family code EE and has an included temperature
       sensor. The EF devices have no temperature sensor,

   UVI
       The  UVI	 sensor is an implementation of the EE class device with Ultra
       Violet Index sensing. All it's specific	properties  are	 in  the  UVI/
       directory.

ADDRESSING
DATASHEET
       UVI    http://www.hobby-boards.com/cata‐
	      log/links/uvi2-r1/UVI%20Meter%20User%20Manual.pdf

       Moisture and Leaf Sensor
	      http://www.hobby-boards.com/download/manuals/Mois‐
	      ture%20Meter.pdf

       4 Channel Hub
	      http://www.hobby-boards.com/download/manuals/4%20Chan‐
	      nel%20Hub.pdf

SEE ALSO
AVAILABILITY
       http://www.owfs.org

AUTHOR
       Paul Alfille (paul.alfille@gmail.com)

OWFS Manpage			     2009		  HobbyBoards_EE/EF(3)
[top]

List of man pages available for DragonFly

Copyright (c) for man pages and the logo by the respective OS vendor.

For those who want to learn more, the polarhome community provides shell access and support.

[legal] [privacy] [GNU] [policy] [cookies] [netiquette] [sponsors] [FAQ]
Tweet
Polarhome, production since 1999.
Member of Polarhome portal.
Based on Fawad Halim's script.
....................................................................
Vote for polarhome
Free Shell Accounts :: the biggest list on the net