ipmiconsole(8)			System Commands			ipmiconsole(8)

NAME
       ipmiconsole - IPMI console utility

SYNOPSIS
       ipmiconsole [OPTION...]

DESCRIPTION
       ipmiconsole  is a Serial-over-LAN (SOL) console utility. It can be used
       to establish console sessions to remote machines using the IPMI 2.0 SOL
       protocol.

       Ipmiconsole  communicates  with a remote machine's Baseboard Management
       Controller (BMC) to establish a console session. Before any SOL	commu‐
       nication	 can  take  place, the remote machine's BMC must be configured
       properly.  The FreeIPMI tool ipmi-config(8) may be used to do this con‐
       figuration.

       Often  (although	 not always), console redirection must be also be con‐
       figured properly in the BIOS and/or operating system. Both must be con‐
       figured	to  redirect  console  traffic	out  the appropriate COM port.
       Please see your motherboard and OS documentation	 for  instructions  on
       proper setup.

       Listed  below  are general IPMI options, tool specific options, trouble
       shooting	 information,  workaround  information,	 examples,  and	 known
       issues. For a general introduction to FreeIPMI please see freeipmi(7).

GENERAL OPTIONS
       The following options are general options for configuring IPMI communi‐
       cation and executing general tool commands.

       -h IPMIHOST, --hostname=IPMIHOST[:PORT]
	      Specify the remote host to communicate with.  An	optional  port
	      can be specified, which may be useful in port forwarding or sim‐
	      ilar situations.

       -u, --username=USERNAME
	      Specify the username to use when authenticating with the	remote
	      host.   If  not  specified,  a null (i.e. anonymous) username is
	      assumed. The user must a high enough privilege  to  establish  a
	      SOL session and have SOL session abilities.

       -p PASSWORD, --password=PASSWORD
	      Specify the password to use when authenticationg with the remote
	      host.  If not specified, a null  password	 is  assumed.  Maximum
	      password length is 16 for IPMI 1.5 and 20 for IPMI 2.0.

       -P, --password-prompt
	      Prompt  for  password  to	 avoid	possibility  of	 listing it in
	      process lists.

       -k K_G, --k-g=K_G
	      Specify the K_g BMC key to  use  when  authenticating  with  the
	      remote  host  for	 IPMI  2.0.  If	 not  specified, a null key is
	      assumed. To input the key in hexadecimal form, prefix the string
	      with  '0x'.  E.g.,  the key 'abc' can be entered with the either
	      the string 'abc' or the string '0x616263'

       -K, --k-g-prompt
	      Prompt for k-g to avoid possibility of  listing  it  in  process
	      lists.

       --session-timeout=MILLISECONDS
	      Specify  the  session timeout in milliseconds. Defaults to 60000
	      milliseconds (60 seconds) if not specified.

       --retransmission-timeout=MILLISECONDS
	      Specify  the  packet  retransmission  timeout  in	 milliseconds.
	      Defaults to 500 milliseconds (0.5 seconds) if not specified.

       -I, --cipher-suite-id=CIPHER-SUITE-ID
	      Specify the IPMI 2.0 cipher suite ID to use. The Cipher Suite ID
	      identifies a set of authentication, integrity, and confidential‐
	      ity  algorithms to use for IPMI 2.0 communication. The authenti‐
	      cation algorithm identifies the algorithm	 to  use  for  session
	      setup,  the  integrity algorithm identifies the algorithm to use
	      for session packet signatures, and the confidentiality algorithm
	      identifies the algorithm to use for payload encryption. Defaults
	      to cipher suite ID 3 if not specified. The user should be	 aware
	      that  only  cipher  suite	 ids 3, 8, and 12 encrypt console pay‐
	      loads. Console information will be  sent	in  the	 clear	if  an
	      alternate	 cipher	 suite	id  is	selected. The following cipher
	      suite ids are currently supported:

	      0 - Authentication Algorithm = None; Integrity Algorithm = None;
	      Confidentiality Algorithm = None

	      1	 - Authentication Algorithm = HMAC-SHA1; Integrity Algorithm =
	      None; Confidentiality Algorithm = None

	      2 - Authentication Algorithm = HMAC-SHA1; Integrity Algorithm  =
	      HMAC-SHA1-96; Confidentiality Algorithm = None

	      3	 - Authentication Algorithm = HMAC-SHA1; Integrity Algorithm =
	      HMAC-SHA1-96; Confidentiality Algorithm = AES-CBC-128

	      6 - Authentication Algorithm = HMAC-MD5; Integrity  Algorithm  =
	      None; Confidentiality Algorithm = None

	      7	 -  Authentication Algorithm = HMAC-MD5; Integrity Algorithm =
	      HMAC-MD5-128; Confidentiality Algorithm = None

	      8 - Authentication Algorithm = HMAC-MD5; Integrity  Algorithm  =
	      HMAC-MD5-128; Confidentiality Algorithm = AES-CBC-128

	      11  - Authentication Algorithm = HMAC-MD5; Integrity Algorithm =
	      MD5-128; Confidentiality Algorithm = None

	      12 - Authentication Algorithm = HMAC-MD5; Integrity Algorithm  =
	      MD5-128; Confidentiality Algorithm = AES-CBC-128

	      15 - Authentication Algorithm = HMAC-SHA256; Integrity Algorithm
	      = None; Confidentiality Algorithm = None

	      16 - Authentication Algorithm = HMAC-SHA256; Integrity Algorithm
	      = HMAC_SHA256_128; Confidentiality Algorithm = None

	      17 - Authentication Algorithm = HMAC-SHA256; Integrity Algorithm
	      = HMAC_SHA256_128; Confidentiality Algorithm = AES-CBC-128

       -l PRIVILEGE-LEVEL, --privilege-level=PRIVILEGE-LEVEL
	      Specify the privilege level to be used. The currently  available
	      privilege	 levels	 are  USER,  OPERATOR,	and ADMIN. Defaults to
	      ADMIN if not specified.

       --config-file=FILE
	      Specify an alternate configuration file.

       -W WORKAROUNDS, --workaround-flags=WORKAROUNDS
	      Specify workarounds to vendor compliance issues. Multiple	 work‐
	      arounds  can be specified separated by commas. A special command
	      line flag of "none", will indicate no workarounds (may be useful
	      for overriding configured defaults). See WORKAROUNDS below for a
	      list of available workarounds.

       --debug
	      Turn on debugging.

       -?, --help
	      Output a help list and exit.

       --usage
	      Output a usage message and exit.

       -V, --version
	      Output the program version and exit.

IPMICONSOLE OPTIONS
       The following options are specific to Ipmiconsole.

       -e CHAR, --escape-char=CHAR
	      Specify an alternate escape character (default char '&').

       --dont-steal
	      Do not steal an SOL session if one is already detected as	 being
	      in use. Under most circumstances, if SOL is detected as being in
	      use, ipmiconsole will attempt to steal the SOL session away from
	      the  previous session.  This default behavior exists for several
	      reasons, most notably that earlier SOL  sessions	may  have  not
	      been able to be deactivate properly.

       --deactivate
	      Deactivate  SOL  session	if one is detected as being in use and
	      exit.

       --serial-keepalive
	      Occasionally send NUL characters to detect inactive serial  con‐
	      nections.	 This  option  is  particularly	 useful	 for those who
	      intend to run ipmiconsole without much interaction, such as  for
	      logging  purposes.  While	 IPMI  connections may still be alive,
	      some motherboards have exhibited bugs in which underlying serial
	      data can no longer be sent/received. From the viewpoint of ipmi‐
	      console, data is simply not be sent out of the remote system and
	      this problem is only detected once there is user interaction. By
	      sending the occasional NUL character,  the  underlying  loss  of
	      serial  data transfer can be detected far more quickly. There is
	      some risk with this option, as the NUL character byte may affect
	      the  remote  system  depending on what data it may or may not be
	      expecting.

       --serial-keepalive-empty
	      This option is identical to --serial-keepalive except  that  SOL
	      packets  will  contain  no  NUL  character data. On some mother‐
	      boards, this may be sufficient to deal with a hanging IPMI  ses‐
	      sion  without the risk of regularly sending a NUL character byte
	      may have. However, some systems may not ACK a SOL packet without
	      character	 data  in it, meaning these keepalive packets do noth‐
	      ing.

       --sol-payload-instance=NUM
	      Specify the SOL payload instance number. The default value is 1,
	      valid  values  range  from  1 to 15. Most systems only support a
	      single instance, however a few allow users to access multiple.

       --deactivate-all-instances
	      When used along with the --deactivate  option,  will  deactivate
	      all  active  SOL instances instead of just the currently config‐
	      ured payload instance.

       --lock-memory
	      Lock sensitive information (such as usernames and passwords)  in
	      memory.

ESCAPE CHARACTERS
       The  following  escape  sequences  are supported. The default supported
       escape character is '&', but can be changed with the -e option.

       &?     Display a list of currently available escape sequences.

       &.     Terminate the connection.

       &B     Send a "serial-break" to the remote console.

       &D     Send a DEL character.

       &&     Send a single escape character.

GENERAL TROUBLESHOOTING
       Most often, IPMI problems are due to configuration problems.

       IPMI over  LAN  problems	 involve  a  misconfiguration  of  the	remote
       machine's  BMC.	Double check to make sure the following are configured
       properly in the remote machine's BMC: IP address, MAC  address,	subnet
       mask,  username,	 user enablement, user privilege, password, LAN privi‐
       lege, LAN enablement, and allowed authentication type(s). For IPMI  2.0
       connections,  double  check  to make sure the cipher suite privilege(s)
       and K_g key are configured properly. The	 ipmi-config(8)	 tool  can  be
       used to check and/or change these configuration settings.

       In  addition  to the troubleshooting tips below, please see WORKAROUNDS
       below to also if there are any vendor specific bugs that have been dis‐
       covered and worked around.

       Listed  below  are  many	 of the common issues for error messages.  For
       additional support, please e-mail the <freeipmi-users@gnu.org>  mailing
       list.

       "username  invalid"  - The username entered (or a NULL username if none
       was entered) is not available on the remote machine.  It	 may  also  be
       possible the remote BMC's username configuration is incorrect.

       "password  invalid"  - The password entered (or a NULL password if none
       was entered) is not correct. It may also be possible the	 password  for
       the user is not correctly configured on the remote BMC.

       "password  verification timeout" - Password verification has timed out.
       A "password invalid" error (described  above)  or  a  generic  "session
       timeout" (described below) occurred.  During this point in the protocol
       it cannot be differentiated which occurred.

       "k_g invalid" - The K_g key entered (or a NULL  K_g  key	 if  none  was
       entered)	 is  not  correct.  It may also be possible the K_g key is not
       correctly configured on the remote BMC.

       "privilege level insufficient" - An IPMI command requires a higher user
       privilege  than	the one authenticated with. Please try to authenticate
       with a higher privilege. This may require authenticating to a different
       user which has a higher maximum privilege.

       "privilege  level  cannot  be  obtained	for this user" - The privilege
       level you are attempting to authenticate with is higher than the	 maxi‐
       mum  allowed for this user. Please try again with a lower privilege. It
       may also be possible the maximum privilege level allowed for a user  is
       not configured properly on the remote BMC.

       "authentication	type  unavailable for attempted privilege level" - The
       authentication type you wish to authenticate with is not available  for
       this privilege level. Please try again with an alternate authentication
       type or alternate privilege level. It may also be possible  the	avail‐
       able  authentication  types you can authenticate with are not correctly
       configured on the remote BMC.

       "cipher suite id unavailable" - The cipher suite id you wish to authen‐
       ticate  with  is not available on the remote BMC. Please try again with
       an alternate cipher suite id. It may also  be  possible	the  available
       cipher suite ids are not correctly configured on the remote BMC.

       "ipmi  2.0  unavailable"	 -  IPMI  2.0 was not discovered on the remote
       machine. Please try to use IPMI 1.5 instead.

       "connection timeout" - Initial IPMI communication failed. A  number  of
       potential errors are possible, including an invalid hostname specified,
       an IPMI IP address cannot be resolved,  IPMI  is	 not  enabled  on  the
       remote  server,	the network connection is bad, etc. Please verify con‐
       figuration and connectivity.

       "session timeout" - The IPMI session has timed out.  Please  reconnect.
       If this error occurs often, you may wish to increase the retransmission
       timeout. Some remote BMCs are considerably slower than others.

       "internal IPMI error" - An IPMI error has occurred that	FreeIPMI  does
       not  know  how  to  handle.  Please  e-mail <freeipmi-users@gnu.org> to
       report the issue.

IPMICONSOLE TROUBLESHOOTING
       The following are common issues for error messages in ipmiconsole.

       "SOL unavailable" - SOL is not configured for use on  the  remote  BMC.
       It may be not configured in general or for the specific user specified.
       Authenticating with a different user may	 be  sufficient,  however  the
       IPMI  protocol  does not reveal detail on what is not configured on the
       remote BMC.

       "SOL in use" - SOL is already in use on the remote BMC. If you  do  not
       specify	the --dont-steal option, ipmiconsole will attempt to steal the
       SOL session away from the other session. Not all BMCs support the abil‐
       ity to steal away a SOL session.

       "SOL session stolen" - Your SOL session has been stolen by another ses‐
       sion. You may wish to try and steal the session back by reconnecting.

       "SOL requires encryption"  -  SOL  requires  a  cipher  suite  id  that
       includes encryption. Please try to use cipher suite id 3, 8, or 12.  It
       may also be possible the encryption  requirements  are  not  configured
       correctly on the remote BMC.

       "SOL requires no encryption" - SOL requires a cipher suite id that does
       not use encryption. Please try to use cipher suite id 0, 1, 2, 6, 7, or
       11. It may also be possible the encryption requirements are not config‐
       ured correctly on the remote BMC.

       "BMC Implementation" - The BMC on the remote machine has a severe prob‐
       lem in its implementation. Please see the WORKAROUNDS section below for
       possible workarounds. If additional vendor  workarounds	are  required,
       please contact the authors.

       "excess	retransmissions sent" - An excessive number of retransmissions
       of SOL packets has occurred and ipmiconsole has given up. This  may  be
       due  to	network issues or SOL issues. Some of the same issues involved
       with "connection timeout" or "session timeout" errors may be  involved.
       Please try to reconnect.

       "excess errors received" - An excessive number of SOL packet errors has
       occurred and ipmiconsole has given up.  This  may  be  due  to  network
       issues or SOL issues.  Please try to reconnect.

       "BMC  Error"  -	This  error  usually means a vendor SOL implementation
       requires a combination of authentication, encryption,  privilege,  etc.
       that have not been met by the user's choices.  Please try a combination
       of different cipher suites, privileges, etc. to	resolve	 the  problem.
       Please see the WORKAROUNDS section below for possible workarounds too.

WORKAROUNDS
       With  so	 many different vendors implementing their own IPMI solutions,
       different vendors may implement their IPMI protocols  incorrectly.  The
       following describes a number of workarounds currently available to han‐
       dle discovered compliance issues. When possible, workarounds have  been
       implemented so they will be transparent to the user. However, some will
       require the user to specify a workaround be used via the -W option.

       The hardware listed below may only indicate the hardware that a problem
       was  discovered	on.  Newer  versions  of hardware may fix the problems
       indicated below. Similar machines from vendors may or may  not  exhibit
       the  same  problems.  Different vendors may license their firmware from
       the same IPMI firmware developer, so it may be worthwhile to try	 work‐
       arounds listed below even if your motherboard is not listed.

       If  you	believe	 your hardware has an additional compliance issue that
       needs a workaround to be implemented, please contact the FreeIPMI main‐
       tainers on <freeipmi-users@gnu.org> or <freeipmi-devel@gnu.org>.

       authcap	-  This	 workaround  flag  will skip early checks for username
       capabilities, authentication capabilities, and K_g  support  and	 allow
       IPMI  authentication  to	 succeed.  It  works around multiple issues in
       which the remote system does not properly report username capabilities,
       authentication  capabilities,  or  K_g status. Those hitting this issue
       may  see	 "username  invalid",  "authentication	type  unavailable  for
       attempted privilege level", or "k_g invalid" errors.  Issue observed on
       Asus  P5M2/P5MT-R/RS162-E4/RX4,	Intel  SR1520ML/X38ML,	and  Sun  Fire
       2200/4150/4450 with ELOM.

       nochecksumcheck	- This workaround flag will tell FreeIPMI to not check
       the checksums returned from IPMI command	 responses.  It	 works	around
       systems that return invalid checksums due to implementation errors, but
       the packet is otherwise valid. Users are cautioned on the use  of  this
       option,	as  it	removes	 validation of packet integrity in a number of
       circumstances. However, it is unlikely to be an issue  in  most	situa‐
       tions.  Those hitting this issue may see "connection timeout", "session
       timeout", or "password verification timeout" errors. On IPMI  1.5  con‐
       nections,  the  "noauthcodecheck" workaround may also needed too. Issue
       observed on Supermicro X9SCM-iiF, Supermicro  X9DRi-F,  and  Supermicro
       X9DRFR.

       intel20	- This workaround flag will work around several Intel IPMI 2.0
       authentication issues. The issues covered include padding of usernames,
       and  password  truncation  if  the  authentication  algorithm  is HMAC-
       MD5-128. Those hitting this issue may see "username invalid", "password
       invalid",  or  "k_g  invalid" errors. Issue observed on Intel SE7520AF2
       with Intel Server Management Module (Professional Edition).

       supermicro20 - This workaround flag will work around several Supermicro
       IPMI  2.0  authentication  issues  on  motherboards  w/	Peppercon IPMI
       firmware. The issues covered include handling invalid length  authenti‐
       cation  codes.  Those  hitting  this  issue  may see "password invalid"
       errors.	Issue observed on Supermicro H8QME with SIMSO  daughter	 card.
       Confirmed fixed on newerver firmware.

       sun20 - This workaround flag will work work around several Sun IPMI 2.0
       authentication issues. The issues covered include invalid lengthed hash
       keys,  improperly  hashed keys, and invalid cipher suite records. Those
       hitting this issue may see "password invalid" or	 "bmc  error"  errors.
       Issue  observed	on Sun Fire 4100/4200/4500 with ILOM.  This workaround
       automatically includes the "opensesspriv" workaround.

       opensesspriv - This workaround flag will slightly alter FreeIPMI's IPMI
       2.0 connection protocol to workaround an invalid hashing algorithm used
       by the remote system. The privilege level sent during the Open  Session
       stage of an IPMI 2.0 connection is used for hashing keys instead of the
       privilege level sent during the RAKP1 connection stage.	Those  hitting
       this  issue may see "password invalid", "k_g invalid", or "bad rmcpplus
       status code" errors.  Issue observed on Sun  Fire  4100/4200/4500  with
       ILOM, Inventec 5441/Dell Xanadu II, Supermicro X8DTH, Supermicro X8DTG,
       Intel S5500WBV/Penguin Relion 700, Intel S2600JF/Appro 512X, and Quanta
       QSSC-S4R/Appro  GB812X-CN.  This	 workaround is automatically triggered
       with the "sun20" workaround.

       integritycheckvalue - This workaround flag will work around an  invalid
       integrity  check	 value	during	an IPMI 2.0 session establishment when
       using Cipher Suite ID 0. The integrity check value should be 0  length,
       however	the  remote motherboard responds with a non-empty field. Those
       hitting this issue may see "k_g	invalid"  errors.  Issue  observed  on
       Supermicro  X8DTG,  Supermicro X8DTU, and Intel S5500WBV/Penguin Relion
       700, and Intel S2600JF/Appro 512X.

       solpayloadsize - This workaround flag will not check for valid SOL pay‐
       load sizes and assume a proper set. It works around remote systems that
       report invalid IPMI 2.0 SOL payload sizes. Those hitting this issue may
       see    "BMC    Implementation"	errors.	  Issue	  observed   on	  Asus
       P5M2/RS162-E4/RX4, Intel SR1520ML/X38ML, Inventec 5441/Dell Xanadu  II,
       Sun  x4100,  Supermicro	X8DTH, Supermicro X8DTG, Supermicro X8DTU, and
       Quanta QSSC-S4R//Appro GB812X-CN.

       solport - This workaround flag will ignore alternate SOL	 ports	speci‐
       fied  during  the  protocol. It works around remote systems that report
       invalid alternate SOL ports. Those hitting this issue may see  "connec‐
       tion  timeout"  errors.	Issue  observed	 on Asus P5MT-R and Supermicro
       X8DTH-iF.

       solstatus - This workaround flag will not check the current  activation
       status of SOL during the protocol setup. It works around remote systems
       that do not properly support this command. Those hitting this issue may
       see "BMC Error" errors. Issue observed on Supermicro X8SIL-F.

       solchannelsupport  - This workaround flag will not check if SOL is sup‐
       ported on the current channel. It works around remote systems  that  do
       not  properly  support  this  command. Those hitting this issue may see
       "BMC Error" errors. Issue observed on Intel  Windmill,  Quanta  Winter‐
       fell, and Wiwynn Windmill

       serialalertsdeferred - This workaround option will set serial alerts to
       be deferred instead of have them be failures. This works around mother‐
       boards  that  perform IPMI over serial along with IPMI serial over LAN.
       Those hitting this issue may see	 "excess  retransmissions  sent"  when
       they  attempt to input data via SOL.  Issue observed on Intel Windmill,
       Quanta Winterfell, and Wiwynn Windmill.

       solpacketseq - This workaround option will increment  the  SOL  payload
       packet  sequence	 number	 under dire circumstances. Normally SOL should
       never do this, however some motherboards have shown to get "stuck"  due
       to an internal bug on the motherboard. This workaround can help in get‐
       ting the BMC  un-stuck.	Those  hitting	this  issue  may  see  "excess
       retransmissions	sent"  when  they attempt to input data via SOL. Issue
       observed on Intel Windmill, Quanta Winterfell, and Wiwynn Windmill.

KNOWN ISSUES
       On older operating systems, if you input your username,	password,  and
       other  potentially  security  relevant information on the command line,
       this information may be discovered by other users when using tools like
       the  ps(1) command or looking in the /proc file system. It is generally
       more secure to input password information with options like the	-P  or
       -K  options.  Configuring security relevant information in the FreeIPMI
       configuration file would also be an appropriate way to hide this infor‐
       mation.

       In  order  to  prevent  brute force attacks, some BMCs will temporarily
       "lock up" after a number of remote authentication errors. You may  need
       to  wait awhile in order to this temporary "lock up" to pass before you
       may authenticate again.

       Some motherboards define an OEM SOL inactivity  timeout	for  SOL  ses‐
       sions. If SOL sessions stay inactive for long periods of time, ipmicon‐
       sole sessions may be abruptly closed, most likely resulting in  session
       timeout	errors. Please see OEM notes for information on modifying this
       parameter if you wish for sessions to stay active longer.

SPECIFIC HARDWARE NOTES
       Intel SR1520ML/X38ML: After a reboot, the SOL session appears to	 "dis‐
       connect"	 from  the  motherboard	 but stay alive.  Character data input
       from the ipmiconsole client is accepted by the remote machine,  but  no
       character  data	or  console  data  is  ever  sent back from the remote
       machine. The SOL session is subsequently useless. There is currently no
       workaround  in  place  to  handle  this. The session must be closed and
       restarted.

EXAMPLES
       # ipmiconsole -h ahost -u myusername -p mypassword

       Establish a console sesssion with a remote host.

REPORTING BUGS
       Report bugs to <freeipmi-users@gnu.org> or <freeipmi-devel@gnu.org>.

COPYRIGHT
       Copyright (C) 2007-2015 Lawrence Livermore National Security, LLC.
       Copyright (C) 2006-2007 The Regents of the University of California.

       This program is free software; you can redistribute it and/or modify it
       under  the  terms of the GNU General Public License as published by the
       Free Software Foundation; either version 3 of the License, or (at  your
       option) any later version.

SEE ALSO
       freeipmi.conf(5), freeipmi(7), ipmi-config(8)

       http://www.gnu.org/software/freeipmi/

ipmiconsole 1.5.1		  2016-02-18			ipmiconsole(8)
[top]

List of man pages available for DragonFly

Copyright (c) for man pages and the logo by the respective OS vendor.

For those who want to learn more, the polarhome community provides shell access and support.

[legal] [privacy] [GNU] [policy] [cookies] [netiquette] [sponsors] [FAQ]
Tweet
Polarhome, production since 1999.
Member of Polarhome portal.
Based on Fawad Halim's script.
....................................................................
Vote for polarhome
Free Shell Accounts :: the biggest list on the net