MODBUS_CONNECT(3)	       Libmodbus Manual		     MODBUS_CONNECT(3)

NAME
       modbus_connect - establish a Modbus connection

SYNOPSIS
       int modbus_connect(modbus_t *ctx);

DESCRIPTION
       The modbus_connect() function shall etablish a connection to a Modbus
       server, a network or a bus using the context information of libmodbus
       context given in argument.

RETURN VALUE
       The modbus_connect() function shall return 0 if successful. Otherwise
       it shall return -1 and set errno to one of the values defined by the
       system calls of the underlying platform.

EXAMPLE
	   modbus_t *ctx;

	   ctx = modbus_new_tcp("127.0.0.1", 502);
	   if (modbus_connect(ctx) == -1) {
	       fprintf(stderr, "Connection failed: %s\n", modbus_strerror(errno));
	       modbus_free(ctx);
	       return -1;
	   }

SEE ALSO
       modbus_close(3)

AUTHORS
       The libmodbus documentation was written by Stéphane Raimbault
       <stephane.raimbault@gmail.com[1]>

NOTES
	1. stephane.raimbault@gmail.com
	   mailto:stephane.raimbault@gmail.com

libmodbus 3.1.0			  10/06/2013		     MODBUS_CONNECT(3)
[top]

List of man pages available for DragonFly

Copyright (c) for man pages and the logo by the respective OS vendor.

For those who want to learn more, the polarhome community provides shell access and support.

[legal] [privacy] [GNU] [policy] [cookies] [netiquette] [sponsors] [FAQ]
Tweet
Polarhome, production since 1999.
Member of Polarhome portal.
Based on Fawad Halim's script.
....................................................................
Vote for polarhome
Free Shell Accounts :: the biggest list on the net