MODBUS_RTU_GET_SERIA(3)	       Libmodbus Manual	       MODBUS_RTU_GET_SERIA(3)

NAME
       modbus_rtu_get_serial_mode - get the current serial mode

SYNOPSIS
       int modbus_rtu_get_serial_mode(modbus_t *ctx);

DESCRIPTION
       The modbus_rtu_get_serial_mode() function shall return the serial mode
       currently used by the libmodbus context:

       MODBUS_RTU_RS232
	   the serial line is set for RS232 communication. RS-232 (Recommended
	   Standard 232) is the traditional name for a series of standards for
	   serial binary single-ended data and control signals connecting
	   between a DTE (Data Terminal Equipment) and a DCE (Data
	   Circuit-terminating Equipment). It is commonly used in computer
	   serial ports

       MODBUS_RTU_RS485
	   the serial line is set for RS485 communication. EIA-485, also known
	   as TIA/EIA-485 or RS-485, is a standard defining the electrical
	   characteristics of drivers and receivers for use in balanced
	   digital multipoint systems. This standard is widely used for
	   communications in industrial automation because it can be used
	   effectively over long distances and in electrically noisy
	   environments.

       This function is only available on Linux kernels 2.6.28 onwards and can
       only be used with a context using a RTU backend.

RETURN VALUE
       The modbus_rtu_get_serial_mode() function shall return MODBUS_RTU_RS232
       or MODBUS_RTU_RS485 if successful. Otherwise it shall return -1 and set
       errno to one of the values defined below.

ERRORS
       EINVAL
	   The current libmodbus backend is not RTU.

AUTHORS
       The libmodbus documentation was written by Stéphane Raimbault
       <stephane.raimbault@gmail.com[1]>

NOTES
	1. stephane.raimbault@gmail.com
	   mailto:stephane.raimbault@gmail.com

libmodbus 3.1.0			  10/06/2013	       MODBUS_RTU_GET_SERIA(3)
[top]

List of man pages available for DragonFly

Copyright (c) for man pages and the logo by the respective OS vendor.

For those who want to learn more, the polarhome community provides shell access and support.

[legal] [privacy] [GNU] [policy] [cookies] [netiquette] [sponsors] [FAQ]
Tweet
Polarhome, production since 1999.
Member of Polarhome portal.
Based on Fawad Halim's script.
....................................................................
Vote for polarhome
Free Shell Accounts :: the biggest list on the net