SG3_UTILS(8)			   SG3_UTILS			  SG3_UTILS(8)

NAME
       sg3_utils - a package of utilities for sending SCSI commands

SYNOPSIS
       sg_*  [--help]  [--hex]	[--maxlen=LEN] [--raw] [--verbose] [--version]
       [OTHER_OPTIONS] DEVICE

DESCRIPTION
       sg3_utils is a package of utilities that	 send  SCSI  commands  to  the
       given  DEVICE  via  a  SCSI pass through interface provided by the host
       operating system.

       The names of all utilities start with "sg" and most  start  with	 "sg_"
       often  followed	by  the name, or a shortening of the name, of the SCSI
       command that they send. For example the "sg_verify" utility  sends  the
       SCSI  VERIFY command. A mapping between SCSI commands and the sg3_utils
       utilities that issue them is shown in the COVERAGE file.

       SCSI draft standards can be found at http://www.t10.org . The standards
       themselves  can	be  purchased  from ANSI and other standards organiza‐
       tions.  A good overview of  various  SCSI  standards  can  be  seen  in
       http://www.t10.org/scsi-3.htm  with  the SCSI command sets in the upper
       part of the diagram. SCSI commands in common with all device types  can
       be  found  in  SPC  of  which  SPC-4 is the latest major version. Block
       device specific commands (e.g. as used by disks) are in SBC, those  for
       tape drives in SSC and those for CD/DVD/BD drives in MMC.

       It  is  becoming more common to control ATA disks with the SCSI command
       set.  This involves the translation of SCSI commands  to	 their	corre‐
       sponding	 ATA  equivalents  (and	 that  is an imperfect mapping in some
       cases). The relevant standard is called SCSI to	ATA  Translation  (SAT
       and  SAT-2  are now standards at INCITS(ANSI) and ISO while SAT-3 is at
       the draft stage). The logic to perform the command translation is often
       called  a  SAT  Layer or SATL and may be within an operating system, in
       host bus adapter firmware or in an  external  device  (e.g.  associated
       with a SAS expander). See http://www.t10.org for more information.

       There  is  some	support	 for SCSI tape devices but not for their basic
       commands. The reader is referred to the "mt" utility.

       There are two generations of command line option usage. The newer util‐
       ities (written since July 2004) use the getopt_long() function to parse
       command line options. With that function, each option has two represen‐
       tations: a short form (e.g. '-v') and a longer form (e.g. '--verbose').
       If an argument is required then it follows a space (optionally) in  the
       short  form and a "=" in the longer form (e.g. in the sg_verify utility
       '-l  2a6h'  and	'--lba=2a6h'   are   equivalent).   Note   that	  with
       getopt_long(), short form options can be elided, for example: '-all' is
       equivalent to '-a -l  -l'.   The	 DEVICE	 argument  may	appear	after,
       between or prior to any options.

       The  older  utilities, such as sg_inq, had individual command line pro‐
       cessing code typically based on a single "-" followed by	 one  or  more
       characters.  If	an  argument  is  needed  then	it follows a "=" (e.g.
       '-p=1f' in sg_modes with its older interface). Various options  can  be
       elided  as long as it is not ambiguous (e.g. '-vv' to increase the ver‐
       bosity).

       Over time the command line interface of these  older  utilities	became
       messy  and  overloaded  with  options. So in sg3_utils version 1.23 the
       command line interface of these older utilities	was  altered  to  have
       both  a	cleaner	 getopt_long() interface and their older interface for
       backward compatibility.	By default these  older	 utilities  use	 their
       getopt_long()  based interface.	That can be overridden by defining the
       SG3_UTILS_OLD_OPTS environment variable or using '-O' or '--old' as the
       first  command  line option. The man pages of the older utilities docu‐
       ments the details.

       Several sg3_utils utilities are based on	 the  Unix  dd	command	 (e.g.
       sg_dd) and permit copying data at the level of SCSI READ and WRITE com‐
       mands. sg_dd is tightly bound to Linux and hence is not ported to other
       OSes.  A	 more generic utility (than sg_dd) called ddpt in a package of
       the same name has been ported to other OSes.

LINUX DEVICE NAMING
       Normal disk block devices have names like /dev/sda, /dev/sdb, /dev/sdc,
       etc.  SCSI disks in Linux have always had names like that but in recent
       Linux kernels (e.g. lk 2.6 series)  it  is  becoming  more  common  for
       almost  all  disks  to be named like that. Partitions within a disk are
       specified by a number appended to the device name, starting at 1	 (e.g.
       /dev/sda1 ).

       Tape  drives are named /dev/st<num> or /dev/nst<num> where <num> starts
       at zero. Additionally one letter from this list: "lma" may be  appended
       to   the	 name.	CD,  DVD  and  BD  readers  (and  writers)  are	 named
       /dev/sr<num> where <num> start at zero. There are less used SCSI device
       type  names,  the dmesg and the lsscsi commands may help to find if any
       are attached to a running system.

       There is also a SCSI  device  driver  which  offers  alternate  generic
       access  to  SCSI	 devices. It uses names of the form /dev/sg<num> where
       <num> starts at zero. The "lsscsi -g" command may be useful in  finding
       these  and  which  generic name corresponds to a device type name (e.g.
       /dev/sg2 may correspond to /dev/sda). In the lk 2.6 series a block SCSI
       generic	 driver	  was  introduced  and	its  names  are	 of  the  form
       /dev/bsg/<h:c:t:l> where h, c, t and l are numbers. Again see the  lss‐
       csi  command  to	 find the correspondence between that SCSI tuple (i.e.
       <h:c:t:l>) and alternate device names.

       Prior to the Linux kernel 2.6 series these  utilities  could  only  use
       generic device names (e.g. /dev/sg1 ). In almost all cases in the Linux
       kernel 2.6 series, any device name can be used by these utilities.

WINDOWS DEVICE NAMING
       Storage and related devices can have several device names  in  Windows.
       Probably the most common in the volume name (e.g. "D:"). There are also
       a "class" device	 names	such  as  "PhysicalDrive<n>",  "CDROM<n>"  and
       "TAPE<n>". <n> is an integer starting at 0 allocated in ascending order
       as devices are discovered (and sometimes rediscovered).

       Some storage devices have a SCSI lower level device name	 which	starts
       with  a	SCSI  (pseudo) adapter name of the form "SCSI<n>:". To this is
       added sub-addressing in the form of a "bus" number, a "target"  identi‐
       fier and a LUN (Logical Unit Number). The "bus" number is also known as
       a "PathId".  These are assembled to form a device  name	of  the	 form:
       "SCSI<n>:<bus>,<target>,<lun>". The trailing ",<lun>" may be omitted in
       which case a LUN of zero is assumed. This lower level device name  can‐
       not often be used directly since Windows blocks attempts to use it if a
       class driver has "claimed" the device.  There  are  SCSI	 device	 types
       (e.g.   Automation/Drive	 interface  type)  for which there is no class
       driver. At least two transports ("bus types" in	Windows	 jargon):  USB
       and IEEE 1394 do not have a "scsi" device names of this form.

       In  keeping  with DOS file system conventions, the various device names
       can be given in upper, lower or mixed case. Since "PhysicalDrive<n>" is
       tedious to write, a shortened form of "PD<n>" is permitted by all util‐
       ities in this package.

       A single device (e.g. a disk) can have many device names. For  example:
       "PD0"  can  also	 be "C:", "D:" and "SCSI0:0,1,0". The two volume names
       reflect that the disk has two partitions on it.	Disk  partitions  that
       are not recognized by Windows are not usually given a volume name. How‐
       ever Vista does show a volume name for a disk which has	no  partitions
       recognized by it and when selected invites the user to format it (which
       may be rather unfriendly to other OSes).

       These utilities assume a given device  name  is	in  the	 Win32	device
       namespace.  To make that explicit "\\.\" can be prepended to the device
       names mentioned in this section. Beware that  backslash	is  an	escape
       character  in  Unix  like  shells  and the C programming language. In a
       shell like Msys (from MinGW) each backslash may need to be typed twice.

       The sg_scan utility within this package lists out Windows device	 names
       in a form that is suitable for other utilities in this package to use.

FREEBSD DEVICE NAMING
       SCSI  disks have block names of the form /dev/da<num> where <num> is an
       integer starting at zero. The "da" is replaced by "sa"  for  SCSI  tape
       drives  and "cd" for SCSI CD/DVD/BD drives. Each SCSI device has a cor‐
       responding pass-through device name of the  form	 /dev/pass<num>	 where
       <num>  is an integer starting at zero. The "camcontrol devlist" command
       may be useful for finding out which SCSI device names are available and
       the correspondence between class and pass-through names.

SOLARIS DEVICE NAMING
       SCSI  device  names below the /dev directory have a form like: c5t4d3s2
       where the number following "c" is the controller (HBA) number, the num‐
       ber  following  "t" is the target number (from the SCSI parallel inter‐
       face days) and the number following "d" is the LUN. Following  the  "s"
       is  the	slice number which is related to a partition and by convention
       "s2" is the whole disk.

       OpenSolaris also has a c5t4d3p2 form where the number following the "p"
       is  the	partition number apart from "p0" which is the whole disk. So a
       whole disk may be referred to as either c5t4d3, c5t4d3s2 or c5t4d3p0 .

       And these device names are duplicated in	 the  /dev/dsk	and  /dev/rdsk
       directories.  The former is the block device name and the latter is for
       "raw" (or char device) access which is  what  sg3_utils	needs.	So  in
       OpenSolaris  something  of  the form 'sg_inq /dev/rdsk/c5t4d3p0' should
       work.  If it doesn't work then add  a  '-vvv'  option  for  more	 debug
       information.   Trying this form 'sg_inq /dev/dsk/c5t4d3p0' (note "rdsk"
       changed to "dsk") will result in an "inappropriate  ioctl  for  device"
       error.

       The device names within the /dev directory are typically symbolic links
       to much longer topological names in the /device directory.  In  Solaris
       cd/dvd/bd  drives  seem	to be treated as disks and so are found in the
       /dev/rdsk directory. Tape drives appear in the /dev/rmt directory.

       There is also a sgen (SCSI generic) driver which by  default  does  not
       attach  to  any	device.	 See the /kernel/drv/sgen.conf file to control
       what is attached. Any attached device will have a device	 name  of  the
       form /dev/scsi/c5t4d3 .

       Listing available SCSI devices in Solaris seems to be a challenge. "Use
       the 'format' command" advice works but seems a very  dangerous  way  to
       list devices. [It does prompt again before doing any damage.] 'devfsadm
       -Cv' cleans out the clutter in the /dev/rdsk  directory,	 only  leaving
       what is "live". The "cfgadm -v" command looks promising.

EXIT STATUS
       To  aid	scripts	 that  call these utilities, the exit status is set to
       indicate success (0) or failure (1 or more).  Note  that	 some  of  the
       lower  values  correspond to the SCSI sense key values. The exit status
       values are:

       0      success

       1      syntax error. Either illegal command line options, options  with
	      bad arguments or a combination of options that is not permitted.

       2      the  DEVICE  reports  that  it  is  not  ready for the operation
	      requested. The device may be in the process  of  becoming	 ready
	      (e.g.   spinning	up  but	 not at speed) so the utility may work
	      after a wait.

       3      the DEVICE reports a  medium  or	hardware  error	 (or  a	 blank
	      check).  For  example  an attempt to read a corrupted block on a
	      disk will yield this value.

       5      the DEVICE reports an "illegal request" with an additional sense
	      code  other than "invalid command operation code". This is often
	      a supported command with a field set requesting  an  unsupported
	      capability.  For	commands that require a "service action" field
	      this value can indicate  that  the  command  with	 that  service
	      action value is not supported.

       6      the  DEVICE  reports  a "unit attention" condition. This usually
	      indicates that something unrelated to the requested command  has
	      occurred	(e.g.  a  device reset) potentially before the current
	      SCSI command was sent. The requested command has not  been  exe‐
	      cuted  by	 the  device.  Note that unit attention conditions are
	      usually only reported once by a device.

       9      the DEVICE reports an illegal request with an  additional	 sense
	      code  of	"invalid  command  operation code" which means that it
	      doesn't support the requested command.

       11     the DEVICE reports an aborted command.  In  some	cases  aborted
	      commands	can  be	 retried  immediately  (e.g.  if the transport
	      aborted the command due to congestion).

       14     the DEVICE reports a miscompare sense key.  VERIFY  and  COMPARE
	      AND WRITE commands may report this.

       15     the  utility is unable to open, close or use the given DEVICE or
	      some other file. The given file name could be incorrect or there
	      may be permission problems. Adding the '-v' option may give more
	      information.

       20     the DEVICE reports it has a check condition but "no  sense"  and
	      non-zero information in its additional sense codes. Some polling
	      commands (e.g. REQUEST SENSE) can receive this response.

       21     the DEVICE reports a "recovered error".  The  requested  command
	      was  successful.	Most  likely a utility will report a recovered
	      error to stderr and continue, probably leaving the utility  with
	      an exit status of 0 .

       33     the command sent to DEVICE has timed out.

       97     a SCSI command response failed sanity checks.

       98     the  DEVICE  reports  it	has  a	check  condition but the error
	      doesn't fit into any of the above categories.

       99     any errors that can't be categorized into values	1  to  98  may
	      yield  this  value. This includes transport and operating system
	      errors after the command has been sent to the device.

       126    the utility was found but could  not  be	executed.  That	 might
	      occur if the executable does not have execute permissions.

       127    This  is the exit status for utility not found. That might occur
	      when a script calls a utility in this package but the PATH envi‐
	      ronment  variable	 has  not  been properly set up, so the script
	      cannot find the executable.

       128 + <signum>
	      If a signal kills a utility then the exit status is 128 plus the
	      signal number. For example if a segmentation fault occurs then a
	      utility is typically killed by SIGSEGV which according to 'man 7
	      signal'  has an associated signal number of 11; so the exit sta‐
	      tus will be 139 .

       255    the utility tried to yield an exit status of 255 or larger. That
	      should not happen; given here for completeness.

       Most  of	 the  error  conditions	 reported above will be repeatable (an
       example of one that is not is "unit attention") so the utility  can  be
       run again with the '-v' option (or several) to obtain more information.

COMMON OPTIONS
       Arguments  to  long options are mandatory for short options as well. In
       the short form an argument to an option uses zero or more spaces	 as  a
       separator (i.e. the short form does not use "=" as a separator).

       If  an option takes a numeric argument then that argument is assumed to
       be decimal unless otherwise indicated (e.g.  with  a  leading  "0x",  a
       trailing "h" or as noted in the usage message).

       Some  options are used uniformly in most of the utilities in this pack‐
       age. Those options are listed below. Note that there  are  some	excep‐
       tions.

       -h, -?, --help
	      output the usage message then exit. In a few older utilities the
	      '-h' option requests hexadecimal output. In these cases the '-?'
	      option will output the usage message then exit.

       -H, --hex
	      for  SCSI	 commands that yield a non-trivial response, print out
	      that response in ASCII hexadecimal.

       -m, --maxlen=LEN
	      several important SCSI commands (e.g. INQUIRY  and  MODE	SENSE)
	      have  response lengths that vary depending on many factors, only
	      some of which these utilities take  into	account.  The  maximum
	      response	length	is  typically  specified  in  the  'allocation
	      length' field of the cdb. In the absence of this option, several
	      utilities use a default allocation length (sometimes recommended
	      in the SCSI draft standards) or a "double fetch" strategy.   See
	      sg_logs(8)  for  its  description	 of a "double fetch" strategy.
	      These techniques are imperfect and in  the  presence  of	faulty
	      SCSI  targets  can  cause	 problems  (e.g. some USB mass storage
	      devices freeze if they  receive  an  INQUIRY  allocation	length
	      other  than  36).	 Also  use of this option disables any "double
	      fetch" strategy that may have otherwise been used.

       -r, --raw
	      for SCSI commands that yield a non-trivial response, output that
	      response	in  binary to stdout. If any error messages or warning
	      are produced they are usually sent  to  stderr.  Some  utilities
	      that consume data to send to the device along with the SCSI com‐
	      mand, use this option to provide that data or indicate  that  it
	      can be read from stdin.

       -v, --verbose
	      increase	the  level  of	verbosity, (i.e. debug output). Can be
	      used multiple times to further  increase	verbosity.  The	 addi‐
	      tional output is usually sent to stderr.

       -V, --version
	      print the version string and then exit. Each utility has its own
	      version number and date of last code change.

NUMERIC ARGUMENTS
       Many utilities have command line options that take  numeric  arguments.
       These  numeric  arguments  can  be  large  values (e.g. a logical block
       address (LBA) on a disk) and  can  be  inconvenient  to	enter  in  the
       default	decimal	 representation.  So various other representations are
       permitted.

       Multiplicative suffixes are accepted. They are one, two or three letter
       strings appended directly after the number to which they apply:

	  c C	      *1
	  w W	      *2
	  b B	      *512
	  k K KiB     *1024
	  KB	      *1000
	  m M MiB     *1048576
	  MB	      *1000000
	  g G GiB     *(2^30)
	  GB	      *(10^9)
	  t T TiB     *(2^40)
	  TB	      *(10^12)
	  p P PiB     *(2^50)
	  PB	      *(10^15)

       An  example is "2k" for 2048. The large tera and peta suffixes are only
       available for numeric arguments that might require 64 bits to represent
       internally.

       A  suffix  of  the form "x<n>" multiplies the leading number by <n>. An
       example is "2x33" for "66". The leading number cannot be "0" (zero)  as
       that would be interpreted as a hexadecimal number (see below).

       These  multiplicative  suffixes	are  compatible	 with GNU's dd command
       (since 2002) which claims compliance with SI and with IEC 60027-2.

       Alternatively numerical arguments can be given  in  hexadecimal.	 There
       are  two syntaxes. The number can be preceded by either "0x" or "0X" as
       found in the C programming language. The second hexadecimal representa‐
       tion is a trailing "h" or "H" as found in (storage) standards. When hex
       numbers are given, multipliers cannot be used. For example the  decimal
       value "256" can be given as "0x100" or "100h".

SCRIPTS, EXAMPLES and UTILS
       There are several bash shell scripts in the 'scripts' subdirectory that
       invoke compiled utilities (e.g. sg_readcap).  The  scripts  start  with
       'scsi_'	rather than 'sg_'. One purpose of these scripts is to call the
       same utility (e.g. sg_readcap) on multiple disks.  Most	of  the	 basic
       compiled utilities only allow one device as an argument. Some distribu‐
       tions install these scripts in a visible directory (e.g. /usr/src/bin).
       Some of these scripts have man page entries. See the README file in the
       'scripts' subdirectory.

       There is some example C code plus examples of  complex  invocations  in
       the 'examples' subdirectory. There is also a README file. The example C
       may be a simpler example of how to use a	 SCSI  pass-through  in	 Linux
       than  the main utilities (found in the 'src' subdirectory). This is due
       to the fewer abstraction layers (e.g. they don't	 worry	the  MinGW  in
       Windows may open a file in text rather than binary mode).

       Some utilities that the author has found useful have been placed in the
       'utils' subdirectory.

WEB SITE
       There	is    a	   web	  page	  discussing	this	package	    at
       http://sg.danny.cz/sg/sg3_utils.html  .	The device naming used by this
       package	 on   various	operating    systems	is    discussed	   at:
       http://sg.danny.cz/sg/device_name.html .

AUTHORS
       Written	by  Douglas Gilbert. Some utilities have been contributed, see
       the CREDITS file and individual source files (in the 'src' directory).

REPORTING BUGS
       Report bugs to <dgilbert at interlog dot com>.

COPYRIGHT
       Copyright © 1999-2014 Douglas Gilbert
       Some utilities are distributed under a GPL version 2 license while oth‐
       ers,  usually  more recent ones, are under a FreeBSD license. The files
       that are common to almost all utilities and thus contain the most reus‐
       able	code,	  namely     sg_lib.[hc],    sg_cmds_basic.[hc]	   and
       sg_cmds_extra.[hc] are under a FreeBSD license. There is	 NO  warranty;
       not even for MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.

SEE ALSO
       sdparm(sdparm), ddpt(ddpt), lsscsi(lsscsi), dmesg(1), mt(1)

sg3_utils-1.38			  March 2014			  SG3_UTILS(8)
[top]

List of man pages available for Alpinelinux

Copyright (c) for man pages and the logo by the respective OS vendor.

For those who want to learn more, the polarhome community provides shell access and support.

[legal] [privacy] [GNU] [policy] [cookies] [netiquette] [sponsors] [FAQ]
Tweet
Polarhome, production since 1999.
Member of Polarhome portal.
Based on Fawad Halim's script.
....................................................................
Vote for polarhome
Free Shell Accounts :: the biggest list on the net