SG_READCAP(8)			   SG3_UTILS			 SG_READCAP(8)

NAME
       sg_readcap - send SCSI READ CAPACITY command

SYNOPSIS
       sg_readcap  [--16]  [--brief]  [--help]	[--hex]	 [--lba=LBA]  [--long]
       [--pmi] [--raw] [--verbose] [--version] DEVICE

       sg_readcap [-16] [-b] [-h] [-H] [-lba=LBA] [-pmi] [-r] [-v] [-V] DEVICE

DESCRIPTION
       The normal action of the SCSI READ CAPACITY command  is	to  fetch  the
       number of blocks (and block size) from the DEVICE.

       The  SCSI  READ	CAPACITY  command  (both 10 and 16 byte cdbs) actually
       yield the block address of the last block and the block size. The  num‐
       ber  of blocks is thus one plus the block address of the last block (as
       blocks are counted origin zero (i.e. starting at block zero)). This  is
       the source of many "off by one" errors.

       The  READ  CAPACITY(16)	response  provides  additional information not
       found in the READ CAPACITY(10) response. This includes  protection  and
       logical	block  provisioning  information,  plus	 the number of logical
       blocks per physical block. So even though the media size may not exceed
       what  READ CAPACITY(10) can show, it may still be useful to examine the
       response to READ CAPACITY(16). Sadly there are  horrible	 SCSI  command
       set  implementations  in the wild that crash when the READ CAPACITY(16)
       command is sent to them.

       Device capacity is the product of the number of	blocks	by  the	 block
       size.   This  utility  outputs this figure in bytes, MiB (1048576 bytes
       per MiB) and GB (1000000000 bytes per GB).

       If sg_readcap is called without the --long option then the 10 byte  cdb
       version	(i.e. READ CAPACITY (10)) is sent to the DEVICE. If the number
       of blocks in the response is reported as 0xffffffff (i.e. (2**32 - 1) )
       and  the	 --hex	option	has not been given, then READ CAPACITY (16) is
       called and its response is output.

       This utility supports two command line syntaxes, the preferred  one  is
       shown first in the synopsis and explained in this section. A later sec‐
       tion on the old command	line  syntax  outlines	the  second  group  of
       options.

OPTIONS
       Arguments to long options are mandatory for short options as well.

       -b, --brief
	      outputs two hex numbers (prefixed with '0x' and space separated)
	      to stdout. The first number is the maximum number of  blocks  on
	      the  device  (which  is  one plus the lba of the last accessible
	      block). The second number is the size in bytes of each block. If
	      the operation fails then "0x0 0x0" is written to stdout.

       -h, --help
	      print out the usage message then exit.

       -H, --hex
	      output  the response to the READ CAPACITY command (either the 10
	      or 16 byte cdb variant) in ASCII hexadecimal on stdout.

       -L, --lba=LBA
	      used in conjunction with --pmi  option.  This  variant  of  READ
	      CAPACITY	will yield the last block address after LBA prior to a
	      delay. For a disk, given a LBA it yields	the  highest  numbered
	      block on the same cylinder (i.e. before the heads need to move).
	      LBA is assumed to be decimal unless prefixed by "0x" or it has a
	      trailing	"h".  Defaults to 0.  This option was made obsolete in
	      SBC-3 revision 26.

       -l, --long
	      Use the 16 byte cdb variant of the READ  CAPACITY	 command.  The
	      default  action  is  to use the 10 byte cdb variant which limits
	      the maximum block address to (2**32 - 2). When  a	 10  byte  cdb
	      READ  CAPACITY  command  is  used	 on a device whose size is too
	      large then a last block address of 0xffffffff  is	 returned  (if
	      the device complies with SBC-2).

       --16   Use  the	16  byte cdb variant of the READ CAPACITY command. See
	      the '--long' option.

       -O, --old
	      switch to older style options.

       -p, --pmi
	      partial medium indicator: for finding  the  next	block  address
	      prior to some delay (e.g. head movement). In the absence of this
	      option, the total number of blocks and the  block	 size  of  the
	      device  are  output.   Used  in  conjunction  with the --lba=LBA
	      option. This option was made obsolete in SBC-3 revision 26.

       -r, --raw
	      output response in binary to stdout.

       -v, --verbose
	      increase level of verbosity. Can be used multiple times.

       -V, --version
	      outputs version string then exits.

NOTES
       In the 2.4 series of Linux kernels the DEVICE must be  a	 SCSI  generic
       (sg)  device.  In the 2.6 series block devices (e.g. SCSI disks and DVD
       drives) can also be specified. For example  "sg_readcap	/dev/sda"  and
       "sg_readcap  /dev/hdd" (if /dev/hdd is a ATAPI CD/DVD device) will work
       in the 2.6 series kernels.

EXIT STATUS
       The exit status of sg_readcap is 0 when it is successful. Otherwise see
       the sg3_utils(8) man page.

OLDER COMMAND LINE OPTIONS
       The  options  in	 this  section	were  the only ones available prior to
       sg3_utils version 1.23 . In sg3_utils  version  1.23  and  later	 these
       older  options can be selected by either setting the SG3_UTILS_OLD_OPTS
       environment variable or using '--old' (or '-O) as the first option.

       -16    Use the 16 byte  cdb  variant  of	 the  READ  CAPACITY  command.
	      Equivalent to --long in the main description.

       -b     utility  outputs	two  hex numbers (prefixed with '0x' and space
	      separated) to stdout. The first number is the maximum number  of
	      blocks  on  the  device  (which  is one plus the lba of the last
	      accessible block). The second number is the size of each	block.
	      If  the  operation  fails	 then  "0x0 0x0" is written to stdout.
	      Equivalent to --brief in the main description.

       -h     output the usage message then exit. Giving the  -?  option  also
	      outputs the usage message then exits.

       -H     output  the response to the READ CAPACITY command (either the 10
	      or 16 byte cdb variant) in ASCII hexadecimal on stdout.

       -lba=LBA
	      used in conjunction with	-pmi  option.  This  variant  of  READ
	      CAPACITY	will yield the last block address after LBA prior to a
	      delay.  Equivalent to --lba=LBA in the main description.

       -N     switch to the newer style options.

       -pmi   partial medium indicator: for finding  the  next	block  address
	      prior to some delay (e.g. head movement). In the absence of this
	      switch, the total number of blocks and the  block	 size  of  the
	      device are output.  Equivalent to --pmi in the main description.

       -r     output response in binary (to stdout).

       -v     verbose:	print  out  cdb of issued commands prior to execution.
	      '-vv' and '-vvv' are also accepted yielding greater verbosity.

       -V     outputs version string then exits.

AUTHORS
       Written by Douglas Gilbert

COPYRIGHT
       Copyright © 1999-2012 Douglas Gilbert
       This software is distributed under the GPL version 2. There is NO  war‐
       ranty;  not  even  for MERCHANTABILITY or FITNESS FOR A PARTICULAR PUR‐
       POSE.

SEE ALSO
       sg_inq(sg3_utils)

sg3_utils-1.35			 November 2012			 SG_READCAP(8)
[top]

List of man pages available for SuSE

Copyright (c) for man pages and the logo by the respective OS vendor.

For those who want to learn more, the polarhome community provides shell access and support.

[legal] [privacy] [GNU] [policy] [cookies] [netiquette] [sponsors] [FAQ]
Tweet
Polarhome, production since 1999.
Member of Polarhome portal.
Based on Fawad Halim's script.
....................................................................
Vote for polarhome
Free Shell Accounts :: the biggest list on the net