SG_SENDDIAG(8)			   SG3_UTILS			SG_SENDDIAG(8)

NAME
       sg_senddiag - performs a SCSI SEND DIAGNOSTIC command

SYNOPSIS
       sg_senddiag    [--doff]	  [--extdur]	[--help]    [--hex]   [--list]
       [--maxlen=LEN] [--page=PG]  [--pf]  [--raw=H,H...]  [--raw=-]  [--self‐
       test=ST] [--test] [--uoff] [--verbose] [--version] DEVICE

       sg_senddiag  [-doff]  [-e]  [-h] [-H] [-l] [-pf] [-raw=H,H...] [-raw=-]
       [-s=ST] [-t] [-uoff] [-v] [-V] [-?] DEVICE

DESCRIPTION
       This utility sends a SCSI SEND DIAGNOSTIC command to the DEVICE. It can
       issue  self-tests,  find	 supported  diagnostic pages or send arbitrary
       diagnostic pages.

       When the --list option and a DEVICE are given then the utility sends  a
       SCSI  RECEIVE  DIAGNOSTIC  RESULTS  command to fetch the response (i.e.
       the page numbers of supported diagnostic pages).

       When the --list option is given without a DEVICE then a list  of	 diag‐
       nostic page names and their numbers, known by this utility, are listed.

       This  utility supports two command line syntax-es, the preferred one is
       shown first in the synopsis and explained in this section. A later sec‐
       tion  on	 the  old  command  line  syntax  outlines the second group of
       options.

OPTIONS
       Arguments to long options are mandatory for short options as well.

       -d, --doff
	      set the Device Offline (DevOffL) bit (default  is	 clear).  Only
	      significant when --test option is set for the default self-test.
	      When set other operations on any logical units controlled by the
	      this  device  server  (target) may be affected (delayed) while a
	      default self-test is underway.

       -e, --extdur
	      outputs the expected extended self-test duration.	 The  duration
	      is given in seconds (and minutes in parentheses). This figure is
	      obtained from mode page 0xa (i.e. the control mode page).

       -h, --help
	      print usage message then exit.

       -H, --hex
	      outputs response from RECEIVE DIAGNOSTIC RESULTS in  hex	rather
	      than  decode it.	Only the Supported Diagnostic Pages diagnostic
	      page (i.e. page_code=0) is decoded; other pages (e.g. those used
	      by SES) are output in hex.
	      If  --hex is used once, the hex output has a relative address at
	      the start of each line. If --hex is used twice,  then  ASCII  is
	      shown  to	 the right of each line of hex. If --hex is used three
	      time or more, only the hex is output,  in	 two  character	 pairs
	      (i.e.  a byte) space separated and up to 16 bytes per line. This
	      latter form, if placed in a file or  piped  through  to  another
	      invocation, is suitable for the --raw=- option.

       -l, --list
	      when  a  DEVICE  is also given lists the names of all diagnostic
	      pages supported by this device. The request is sent via  a  SEND
	      DIAGNOSTIC  command  (with the "pF" bit set) and the response is
	      fetched by a RECEIVE DIAGNOSTIC RESULTS command.	When  used  in
	      the  absence of a --list argument then a list of diagnostic page
	      names and their numbers, known by this utility, are listed.

       -m, --maxlen=LEN
	      where LEN is the value placed in the parameter list length field
	      of  a  SEND DIAGNOSTIC command or in the allocation length field
	      of a RECEIVE DIAGNOSTIC RESULTS command. This only  occurs  when
	      the  other  options imply there will be data sent or received by
	      the command. The default value is 4096 bytes. LEN cannot	exceed
	      65535 or 0xffff in hexadecimal.

       -O, --old
	      switch to older style options.

       -P, --page=PG
	      where  PG	 is  the  RECEIVE DIAGNOSTIC RESULTS command page code
	      field.  If this option is given the PCV bit in that  command  is
	      set.  When  this option is given then no SEND DIAGNOSTIC command
	      is sent (unlike --list).	If  PG	is  0  then  the  response  is
	      decoded  as if it is the SPC Supported Diagnostic pages diagnos‐
	      tic page. Other PG values (i.e. 1 to 255) have  their  responses
	      output in hex.

       -p, --pf
	      set Page Format (PF) bit. By default it is clear (i.e. 0) unless
	      the list --list option is given in which case  the  Page	Format
	      bit is set (as required by SPC-3).

       -r, --raw=H,H...
	      string  of  comma	 separated  hex	 numbers  each of which should
	      resolve to a byte value (i.e. 0 to  ff  inclusive).  A  (single)
	      space separated string of hex bytes is also allowed but the list
	      needs to be in quotes. This sequence forms a diagnostic page  to
	      be sent with the SCSI SEND DIAGNOSTIC command. Mostly likely the
	      --pf option should also be given.

       -r, --raw=-
	      reads sequence of bytes from stdin. The sequence may  be	comma,
	      space,  tab  or linefeed (newline) separated. If a line contains
	      "#" then the remaining characters on that line are ignored. Oth‐
	      erwise  each  non	 separator  character should resolve to a byte
	      value (i.e. 0 to ff inclusive). This sequence forms a diagnostic
	      page  to	be  sent with the SCSI SEND DIAGNOSTIC command. Mostly
	      likely the --pf option should also be given.

       -s, --selftest=ST
	      where ST is the self-test code. The default value is 0 which  is
	      inactive. Some other values:
		1 : background short self-test
		2 : background extended self-test
		4 : aborts a (background) self-test that is in progress
		5 : foreground short self-test
		6 : foreground extended self-test
	      This  option  is mutually exclusive with default self-test (i.e.
	      can't have (ST > 0) and --test).

       -t, --test
	      sets the _default_ Self Test (SelfTest) bit. By default this  is
	      clear  (0).   The	 --selftest=ST	option	should	not  be active
	      together with this option. Both the --doff and/or --uoff options
	      can be used with this option.

       -u, --uoff
	      set  the	Unit  Offline  (UnitOffL) bit (default is clear). Only
	      significant when --test option is set for the default self-test.
	      When  set	 other operations on this logical unit may be affected
	      (delayed) while a default self-test is  underway.	 Some  devices
	      (e.g. Fujitsu disks) do more tests when this bit is set.

       -v, --verbose
	      increase level of verbosity. Can be used multiple times.

       -V, --version
	      print out version string then exit.

NOTES
       All devices should support the default self-test. The 'short' self-test
       codes should complete in 2 minutes or less.  The	 'extended'  self-test
       codes'  maximum duration is vendor specific (e.g. a little over 10 min‐
       utes with the author's disks).  The  foreground	self-test  codes  wait
       until  they  are	 completed while the background self-test codes return
       immediately. The results of both foreground  and	 background  self-test
       codes  are placed in the 'self-test results' log page (see sg_logs(8)).
       The SCSI command timeout for this utility is set to 60 minutes to allow
       for slow foreground extended self-tests.

       If  the	DEVICE	is  a  disk then no file systems residing on that disk
       should be mounted during a foreground self-test.	 The  reason  is  that
       other  SCSI  commands may become queued behind the foreground self-test
       and timeout.

       When the --raw=H,H... option is given then  self-tests  should  not  be
       selected. However the --pf (i.e. "page format") option should be given.
       The length of the diagnostic page to be sent is derived from the number
       of  bytes  given	 to  the --raw=H,H... option. The diagnostic page code
       (number) should be the first byte of the sequence (i.e. as dictated  by
       SPC-3 diagnostic page format). See the EXAMPLES section below.

       Arbitrary  diagnostic  pages  can  be  read (in hex) with the sg_ses(8)
       utility (not only those defined in SES-2).

       If the utility is used with no options  (e.g.  "sg_senddiag  /dev/sg1")
       Then a degenerate SCSI SEND DIAGNOSTIC command is sent with zero in all
       its fields apart from the opcode. Some devices report this as an	 error
       while  others  ignore  it. It is not entirely clear from SPC-3 if it is
       invalid to send such a command.

       In the 2.4 series of Linux kernels the DEVICE must be  a	 SCSI  generic
       (sg)  device.  In the 2.6 series block devices (e.g. SCSI disks and DVD
       drives) can also be specified.

       To access SCSI enclosures see the sg_ses(8) utility.  sg_ses  uses  the
       SCSI  SEND  DIAGNOSTIC  and RECEIVE DIAGNOSTIC RESULTS commands as out‐
       lined in the SES-2 (draft) standard.

EXIT STATUS
       The exit status of sg_senddiag is 0 when it  is	successful.  Otherwise
       see the sg3_utils(8) man page.

OLDER COMMAND LINE OPTIONS
       The  options  in	 this  section	were  the only ones available prior to
       sg3_utils version 1.23 . In sg3_utils  version  1.23  and  later	 these
       older  options can be selected by either setting the SG3_UTILS_OLD_OPTS
       environment variable or using '--old' (or '-O) as the first option.

       -doff  set the Device Offline (DevOffL) bit (default  is	 clear).  Only
	      significant  when	 -t  option  is set for the default self-test.
	      Equivalent to --doff in the main description.

       -e     outputs the expected extended self-test duration. Equivalent  to
	      --extdur in the main description.

       -h     outputs  response	 from RECEIVE DIAGNOSTIC RESULTS in hex rather
	      than decode it.

       -H     outputs response from RECEIVE DIAGNOSTIC RESULTS in  hex	rather
	      than decode it.

       -l     when  a  DEVICE  is also given lists the names of all diagnostic
	      pages supported by this device. The request is sent via  a  SEND
	      DIAGNOSTIC  command  (with the "pf" bit set) and the response is
	      fetched by a RECEIVE DIAGNOSTIC RESULTS command.	When  used  in
	      the  absence of a DEVICE argument then a list of diagnostic page
	      names and their numbers, known by this utility, are listed.

       -N     switch to the newer style options.

       -pf    set Page Format (PF) bit. By default it is clear (i.e. 0) unless
	      the  -l option is given in which case the Page Format bit is set
	      (as required by SPC-3).

       -raw=H,H...
	      string of comma separated	 hex  numbers  each  of	 which	should
	      resolve  to a byte value (i.e. 0 to ff inclusive). This sequence
	      forms a diagnostic page to be sent with the SCSI SEND DIAGNOSTIC
	      command. Mostly likely the -pf option should also be given.

       -raw=- reads  sequence  of bytes from stdin. The sequence may be comma,
	      space, tab or linefeed (newline) separated. If a	line  contains
	      "#" then the remaining characters on that line are ignored. Oth‐
	      erwise each non separator character should  resolve  to  a  byte
	      value (i.e. 0 to ff inclusive). This sequence forms a diagnostic
	      page to be sent with the SCSI SEND  DIAGNOSTIC  command.	Mostly
	      likely the -pf option should also be given.

       -s=ST  where  ST is the self-test code. The default value is 0 which is
	      inactive. A value of 1 selects a background short	 self-test;  2
	      selects  a background extended self-test; 5 selects a foreground
	      short self-test; 6 selects a foreground extended test.  A	 value
	      of  4  will  abort a (background) self-test that is in progress.
	      This option is mutually exclusive with default  self-test	 (i.e.
	      -t).

       -t     sets  the _default_ Self Test (SelfTest) bit. By default this is
	      clear (0).  The -s=ST option should not be active together  with
	      this  option.   Both  the -doff and/or -uoff options can be used
	      with this option.

       -uoff  set the Unit Offline (UnitOffL) bit (default is clear).  Equiva‐
	      lent to --uoff in the main description.

       -v     increase level of verbosity. Can be used multiple times.

       -V     print out version string then exit.

       -?     output usage message. Ignore all other parameters.

EXAMPLES
       The examples sub-directory in the sg3_utils packages contains two exam‐
       ple scripts that turn on the CJTPAT (jitter pattern) on some SAS	 disks
       (one script for each phy). One possible invocation for phy 1 is:

	 sg_senddiag --pf --raw=- /dev/sg2 < sdiag_sas_p1_cjtpat.txt

       There  is also an example script that turns on the IDLE pattern. Once a
       test pattern has been started it can be turned off by resetting the phy
       or with the STOP phy pattern function:

	 sg_senddiag --pf --raw=- /dev/sg2 < sdiag_sas_p1_stop.txt

AUTHOR
       Written by Douglas Gilbert

REPORTING BUGS
       Report bugs to <dgilbert at interlog dot com>.

COPYRIGHT
       Copyright © 2003-2015 Douglas Gilbert
       This  software is distributed under the GPL version 2. There is NO war‐
       ranty; not even for MERCHANTABILITY or FITNESS FOR  A  PARTICULAR  PUR‐
       POSE.

SEE ALSO
       sg_ses(8), sg_logs(8), smartmontools(see net)

sg3_utils-1.41			  April 2015			SG_SENDDIAG(8)
[top]

List of man pages available for DragonFly

Copyright (c) for man pages and the logo by the respective OS vendor.

For those who want to learn more, the polarhome community provides shell access and support.

[legal] [privacy] [GNU] [policy] [cookies] [netiquette] [sponsors] [FAQ]
Tweet
Polarhome, production since 1999.
Member of Polarhome portal.
Based on Fawad Halim's script.
....................................................................
Vote for polarhome
Free Shell Accounts :: the biggest list on the net