DS2438(3)		     One-Wire File System		     DS2438(3)

NAME
       DS2438 - Smart Battery Monitor

SYNOPSIS
   Temperature Voltages and Current.
       26  [.]XXXXXXXXXXXX[XX][/[  CA  | EE | date | disconnect/date | discon‐
       nect/udate  |  endcharge/date  |	 endcharge/udate  |  IAD  |  offset  |
       pages/page.[0-7|ALL] | temperature | udate | VAD | VDD | vis | ]]

   Humidity sensor
       26   [.]XXXXXXXXXXXX[XX][/[   HIH4000/humidity	|  HTM1735/humidity  |
       DATANAB/reset | DATANAB/humidity | humidity | temperature ]]

   Barometer
       26   [.]XXXXXXXXXXXX[XX][/[   B1-R1-A/pressure	|    B1-R1-A/gain    |
       B1-R1-A/offset | ]]

   Light
       26   [.]XXXXXXXXXXXX[XX][/[  S3-R1-A/current  |	S3-R1-A/illuminance  |
       S3-R1-A/gain ]]

FAMILY CODE
       26

SPECIAL PROPERTIES
   pages/page.0 ... pages/page.7 pages/page.ALL
       read-write, binary
       Memory is split into 8 pages of 8 bytes each. Only the  pages  3-7  are
       really  available,  and	some  of  that appears to be reserved. See the
       datasheet for details.
       ALL is an aggregate of the pages. Each page is accessed sequentially.

   temperature
       read-only, floating point
       Temperature read by the chip at high resolution (~13 bits).  Units  are
       selected	 from the invoking command line. See owfs(1) or owhttpd(1) for
       choices. Default is Celsius.  Conversion takes ~20 msec.

   VAD VDD
       read-only, floating point
       Voltage read (~10 bits) at the one of the chip's two  supply  voltages.
       Range VDD= 2.4V to 10V, VAD=1.5 to 10V.

   vis
       read-only, floating point
       Current sensor reading, as a voltage difference. Value is in volts.
       Actual current depends on Rsens resistor (see datasheet).
       The formula for current is I = vis / Rsens
       with units in Amps and Ohms.
       Current	measurement  will be temporarily enabled (see Ienable ) if not
       currently enabled (pun intended) for this reading.

CONFIGURATION PROPERTIES
   CA
       read-write, yes-no
       Current Accumulator Configuration flag bit.  If	"on"  (1)  current  is
       stored in page 7 bytes 4-7. If "off" (0) that page can be used for gen‐
       eral storage. See the datasheet for more information.

   EE
       read-write, yes-no
       Current Accumulator Shadow flag bit. If "on"  (1)  current  reading  is
       stored  to  EEPROM. If "off" (0) that data will be lost when chip loses
       power. See the datasheet for more information

   IAD
       read-write, yes-no
       Current A/D Control flag bit. If "on" (1) current measured at 36.41 Hz.
       If  "off" (0) current measurements won't be made. See the datasheet for
       more information.

DATE PROPERTIES
   date
       read-write, ascii
       26 character date representation of the counter value. Increments  once
       per second.
       Setting date to a null string will put the current system time.
       Accepted date formats are:
	 Sat[urday] March 12 12:23:59 2001
	 Apr[il] 4 9:34:56 2002
	 3/23/04 23:34:57
	 current locale setting (your system's format)

   disconnect/date
       read-write, ascii
       26  character  date  representation of the disconnect/udate value. Time
       when the battery pack waws removed from the charger. Format is the same
       as the date property.

   disconnect/udate
       read-write, unsigned integer
       Representation of disconnect/date as a number. See udate for details.

   endcharge/date
       read-write, ascii
       26  character  date representation of the endcharge/udate value. Format
       is the same as the date property.

   endcharge/udate
       read-write, unsigned integer
       Representation of endcharge/date as a number. See udate for details.

   udate
       read-write, unsigned integer
       Time represented as a number.  udate increments once per second.
       Usually set to unix time standard: number of seconds since Jan 1, 1970.
       The  date  field	 will be the unix representation (ascii text) of udate
       and setting either will change the other.

HUMIDITY PROPERTIES
   HIH4000/humidity
       read-only, floating point
       Relative humidity, as percent (1-100 scale).
       This value is for a design based on Honeywell's HIH-4000 humidity  sen‐
       sor.

   HTM1735/humidity
       read-only, floating point
       Relative humidity, as percent (1-100 scale).
       This value is for a design based on Humirel's HTM-1735 humidity sensor.

   DATANAB/humidity
       read-only, floating point
       Based  on  DataNAB's humidity sensor. It uses a HIH-4000 sensor and the
       current sensning rather than voltage readings from the DS2438. Calibra‐
       tion  values  are  stored  on chip, and a check field is stored in chip
       memory.

   DATANAB/reset
       write-only, yes-no
       Used to read calibration values and set the  chip  to  current  reading
       more.  Should  be  automatically	 called	 when  a  humidity  reading is
       requested.

   humidity
       read-only, floating point
       Relative humidity, as percent (1-100 scale).
       The DS2438 actually does not read humidity, but a widely available  and
       publicised circuit based on the chip, does. This design is for the com‐
       mon Honeywell HIH-3610 humidity chip. The  mostly  compatible  HIH-4000
       chip  uses  different  temperature compensation, so is better read from
       the HIH4000/humidity value. See the datasheets for details.
       If the chip is instead a DATANAB	 design,  the  DATANAB/humidity	 value
       will be automatically used.

BAROMETER PROPERTIES
   B1-R1-A/pressure
       read-only, floating point
       Pressure	 reading,  as  milli-bars,  or	other  unit  depending on set‐
       tings/units/pressure_scale.
       This value is for the B1-R1-A barometer from Hobby-Boards, and  assumes
       the standard calibration.

   B1-R1-A/gain
       read/write, floating point
       Calibration  of	pressure gain, as signed number, expressed as the same
       units as B1-R1-A/pressure per volt.
       This value will be multiplied with the  measured	 voltage  to  get  the
       B1-R1-A/pressure	 reading. It may have to be fine tuned for calibration
       purposes, although with the standard sensor,  it	 will  often  be  good
       enough to keep it as is.

   B1-R1-A/offset
       read/write, floating point
       Calibration  of	pressure  offset,  as  signed  number,	same  units as
       B1-R1-A/pressure.
       This value will be added to the B1-R1-A/pressure reading.  The  default
       value  is  904.7	 millibars,  which may be altered to to compensate for
       elevation.

SOLAR SENSOR PROPERTIES
   S3-R1-A/current
       read-only, floating point
       Photo-diode current, in micro-amperes.
       This value is for the S3-R1-A solar radiation sensor from Hobby-Boards.
       Due  to	noise and offsets, this value may read as a negative number in
       low light conditions.  The offset register can be  modified  to	reduce
       the offset as much as possible.

   S3-R1-A/illumination
       read-only, floating point
       Illumination, in lux. Always a positive number.
       This   value   is  the  lux  reading  from  the	solar  sensor,	taking
       S3-R1-A/gain into consideration.

   S3-R1-A/gain
       read/write, floating point
       Calibration of photo-diode gain expressed  as  lux  per	micro-amperes.
       The default value is for the SFH203P photo-diode from Osram, used bare.
       A different gain may be used for instance to compensate	for  an	 inte‐
       grathing, white sphere placed over the diode.
       This value is for the S3-R1-A solar radiation sensor from Hobby-Boards,
       using the SFH203P photo-diode from Osram.

MULTISENSOR PROPERTIES
   MultiSensor/type
       read-only, ascii
       For iButtonLink's MultiSensor line of 1-wire devices, give the specific
       configuration  based  on a data byte set in memory. (Byte 0 of page 3).
       This can help interpretation of the sensor values, distinguishing, cur‐
       rent from water from light.

   offset
       read-write, integer
       Correction  for current readings. A value between -256 and 255. See the
       datasheet for details. Should be set to the negative  of	 a  true  zero
       current reading.

STANDARD PROPERTIES
ALARMS
       None.

DESCRIPTION
   DS2438
       The DS2438 (3) is a more complete form of the DS2436 battery chip. Cur‐
       rent sensing is available, but not  implemented.	 The  major  advantage
       compared	 to  the DS2436 is that two voltages can be read, allowing one
       to correct circuit measurements for supply voltage and  temperature.  A
       better comparison is the DS276x family of chips.

ADDRESSING
DATASHEET
       http://pdfserv.maxim-ic.com/en/ds/DS2438.pdf
       http://pdfserv.maxim-ic.com/en/an/humsensor.pdf
       http://goo.gl/o9DH0  (Redirects	to  009012_2.pdf  PDF  file  on honey‐
       well.com website)
       http://www.phanderson.com/hih-4000.pdf
       http://www.humirel.com/product/fichier/HTM1735%20RevG%20.pdf

SEE ALSO
AVAILABILITY
       http://www.owfs.org

AUTHOR
       Paul Alfille (paul.alfille@gmail.com) Egil Kvaleberg

OWFS Manpage			     2003			     DS2438(3)
[top]

List of man pages available for DragonFly

Copyright (c) for man pages and the logo by the respective OS vendor.

For those who want to learn more, the polarhome community provides shell access and support.

[legal] [privacy] [GNU] [policy] [cookies] [netiquette] [sponsors] [FAQ]
Tweet
Polarhome, production since 1999.
Member of Polarhome portal.
Based on Fawad Halim's script.
....................................................................
Vote for polarhome
Free Shell Accounts :: the biggest list on the net