LOM(4) OpenBSD Programmer's Manual (SPARC64) LOM(4)NAME
lom - lights out management
SYNOPSIS
lom* at ebus?
DESCRIPTION
The lom driver provides support for the LOMlite lights out management
module found on Sun Netra t1 systems and the LOMlite2 module found on Sun
Fire V100/V120 and Sun Netra X1 systems. Temperature readings, PSU
status and fan status provided by the LOM are made available through the
sysctl(8) interface. The integrated watchdog(4) timer can be configured
through the sysctl(8) interface as well. The watchdog timer supports
timeouts between 1 and 126 seconds. If the watchdog is disabled, which
is its default state, it will turn on the system's fault LED after the
maximum timeout of 126 seconds.
The lom driver will update the hostname stored in the LOM whenever the
system's hostname is changed.
SEE ALSOhostname(1), ebus(4), intro(4), watchdog(4), sensorsd(8), sysctl(8)HISTORY
The lom driver first appeared in OpenBSD 4.7.
AUTHORS
The lom driver was written by Mark Kettenis <kettenis@openbsd.org>.
OpenBSD 4.9 September 23, 2009 OpenBSD 4.9