PRTDIAG(1M)PRTDIAG(1M)NAME
prtdiag - display system diagnostic information
SYNOPSIS
/usr/sbin/prtdiag [-v] [-l]
DESCRIPTION
prtdiag displays system configuration and diagnostic information on
sun4u, sun4v, and x86 systems.
The diagnostic information lists any failed field replaceable units
(FRUs) in the system.
The interface, output, and location in the directory hierarchy for prt‐
diag are uncommitted and subject to change in future releases.
prtdiag does not display diagnostic information and environmental sta‐
tus when executed on the Sun Enterprise 10000 server. See the
/var/opt/SUNWssp/adm/${SUNW_HOSTNAME}/messages file on the system ser‐
vice processor (SSP) to obtain such information for this server.
OPTIONS
The following options are supported:
-l
Log output. If failures or errors exist in the system, output
this information to syslogd(1M) only.
-v
Verbose mode. Displays the time of the most recent AC Power fail‐
ure, and the most recent hardware fatal error information, and
(if applicable) environmental status. The hardware fatal error
information is useful to repair and manufacturing for detailed
diagnostics of FRUs.
EXIT STATUS
The following exit values are returned:
0
No failures or errors are detected in the system.
1
Failures or errors are detected in the system.
2
An internal prtdiag error occurred, for example, out of memory.
ATTRIBUTES
See attributes(5) for descriptions of the following attributes:
┌────────────────────┬─────────────────┐
│ ATTRIBUTE TYPE │ ATTRIBUTE VALUE │
├────────────────────┼─────────────────┤
│Interface Stability │ Unstable* │
└────────────────────┴─────────────────┘
*The output is unstable.
SEE ALSOmodinfo(1M), prtconf(1M), psrinfo(1M), sysdef(1M), syslogd(1M),
attributes(5), openprom(7D)NOTES
Not all diagnostic and system information is available on every Solaris
platform, and therefore cannot be displayed by prtdiag. On those plat‐
forms, further information can be obtained from the System Controller.
Sep 2, 2008 PRTDIAG(1M)