ipmiseld.conf(5)		 ipmiseld.conf		      ipmiseld.conf(5)

NAME
       ipmiseld.conf - ipmiseld configuration file

DESCRIPTION
       The ipmiseld configuration file configures the ipmiseld daemon.

       The	  default	configuration	    file       loaded	    is
       /usr/local/etc/freeipmi/ipmiseld.conf.

       The configuration options that can be specified	in  the	 configuration
       file  are  listed  below. Each configuration option must be listed on a
       separate line. Arguments for an option are separated by any  amount  of
       whitespace.  Multiple arguments are also separated by whitespace.  Com‐
       ments can be marked by using the pound sign ("#") character, and	 lines
       can be continued on the next using backslash ("\").

       Note  that  it  is  possible  to	 list the username, password and other
       potentially sensitive information in the configuration  file.  If  this
       data  is	 stored	 in a configuration file, system administrators should
       limit access to this file.

IPMISELD CONFIGURATION OPTIONS
       driver-type IPMIDRIVER
	      Specify the driver type to use.

       disable-auto-probe ENABLE|DISABLE
	      Specify if IPMI devices should be probed for settings.

       driver-address DRIVER-ADDRESS
	      Specify the in-band driver address to use.

       driver-device DEVICE
	      Specify the in-band driver device path to use.

       register-spacing REGISTER-SPACING
	      Specify the in-band driver register spacing to use.

       target-channel-number CHANNEL-NUMBER
	      Specify the in-band driver target channel number.

       target-slave-address SLAVE-ADDRESS
	      Specify the in-band driver target slave address.

       hostname IPMIHOST1,IPMIHOST2,...
	      Specify the remote host(s) to communicate with.  Multiple	 host‐
	      names  may  be separated by comma or may be specified in a range
	      format.

       username USERNAME
	      Specify the username to use.

       password PASSWORD
	      Specify the password to use.

       k_g str
	      Specify the BMC key (K_g) to use. Prefix with '0x' to enter  the
	      key in hex.

       session-timeout MILLISECONDS
	      Specify the session timeout length to use in milliseconds.

       retransmission-timeout MILLISECONDS
	      Specify  the  retransmission  timeout length to use in millisec‐
	      onds.

       authentication-type AUTHENTICATION-TYPE
	      Specify the authentication type to use. The following  authenti‐
	      cation  types  are  supported: NONE, STRAIGHT_PASSWORD_KEY, MD2,
	      and MD5.

       cipher-suite-id CIPHER-SUITE-ID
	      Specify the cipher suite id to use. The following	 cipher	 suite
	      ids are supported: 0, 1, 2, 3, 6, 7, 8, 11, 12.

       privilege-level PRIVILEGE-LEVEL
	      Specify  the privilege type to use. The following privilege lev‐
	      els are supported: USER, OPERATOR, ADMIN.

       workaround-flags WORKAROUNDS
	      Specify workaround flags to use.	Multiple  workarounds  can  be
	      specified	 separated by whitespace. Please see tool manpages for
	      details about available workarounds for each tool. The following
	      workarounds  are	supported:  assumeio,  spinpoll,  idzero, for‐
	      cepermsg, unexpectedauth, endianseq, authcap, intel20,  supermi‐
	      cro20,  sun20,  opensesspriv,  integritycheckvalue, assumesyste‐
	      mevent.

       verbose-count COUNT
	      Specify default verbose count to use for ipmi-sel(8).

       sensors-types TYPE-LIST
	      Specify sensor types of SEL events to log. Multiple types can be
	      specified	 separated  by	whitespace.  Users  may specify sensor
	      types by string or by number (decimal or hex). Please see	 ipmi-
	      sel(8) --list-types option to see possible string input types.

       exclude-sensor-types ENSOR-TYPES-LIST
	      Specify  sensor  types  of SEL events to not log. default sensor
	      types to not show sensor outputs for. Multiple sensor types  can
	      be  specified  separated by whitespace. Users may specify sensor
	      types  by	 string	 or  by	  number.   Please   see   ipmi-sel(8)
	      --list-types option to see possible string input types.

       system-event-only ENABLE|DISABLE
	      Specify if output should only include system event records.

       oem-event-only ENABLE|DISABLE
	      Specify if output should only include OEM event records.

       event-state-config-file FILE
	      Specify the event state configuration file.

       interpret-oem-data ENABLE|DISABLE
	      Specify if ipmiseld should attempt to interpret OEM data or not.

       entity-sensor-names ENABLE|DISABLE
	      Specify  if output of sensor names should include entity ids and
	      instances or not.

       non-abbreviated-units ENABLE|DISABLE
	      Specify if output should have units abbreviated  by  default  or
	      not.

       event-state-filter FILTERSTRING
	      Specify event states to be filtered out and not logged.

       --warning-threshold PERCENTINT
	      Specify SEL fullness warning threshold as an integer percentage.

       --clear-threshold PERCENTINT
	      Specify SEL fullness clear threshold as an integer percentage.

       system-event-format FORMATSTRING
	      Specify  the format of the log output when a SEL system event is
	      encountered.

       oem-timestamped-event-format FORMATSTRING
	      Specify the format of the log output when a SEL OEM  timestamped
	      event is encountered.

       oem-non-timestamped-event-format FORMATSTRING
	      Specify  the  format of the log output when a SEL OEM non-times‐
	      tamped event is encountered.

       poll-interval SECONDS
	      Specify the poll interval to check the SEL for new events.

       log-facility STRING
	      Specify the log facility to use.

       log-priority STRING
	      Specify the log priority to use.

       cache-directory DIRECTORY
	      Specify the cache directory to use.

       ignore-sdr DISABLE
	      Specify if the SDR should be ignored.

       re-download-sdr DISABLE
	      Specify if the SDR should be re-downloaded on start.

       clear-sel DISABLE
	      Specify if the SEL should be cleared on start.

       threadpool-count NUM
	      Specify the threadpool count for parallel SEL polling.

FILES
       /usr/local/etc/freeipmi/ipmiseld.conf

REPORTING BUGS
       Report bugs to <freeipmi-users@gnu.org> or <freeipmi-devel@gnu.org>.

COPYRIGHT
       Copyright (C) 2012-2015 Lawrence Livermore National Security, LLC.

SEE ALSO
       ipmiseld(8), ipmi-sel(8)

       http://www.gnu.org/software/freeipmi/

ipmiseld.conf 1.5.1		  2016-02-18		      ipmiseld.conf(5)
[top]

List of man pages available for DragonFly

Copyright (c) for man pages and the logo by the respective OS vendor.

For those who want to learn more, the polarhome community provides shell access and support.

[legal] [privacy] [GNU] [policy] [cookies] [netiquette] [sponsors] [FAQ]
Tweet
Polarhome, production since 1999.
Member of Polarhome portal.
Based on Fawad Halim's script.
....................................................................
Vote for polarhome
Free Shell Accounts :: the biggest list on the net