sane-epkowa(5)sane-epkowa(5)NAMEsane-epkowa - SANE backend for EPSON scanners
DESCRIPTION
The sane-epkowa library implements a SANE (Scanner Access Now Easy)
backend that provides access to EPSON flatbed scanners. This backend
should be considered alpha-quality software!
At present, the following scanners are known to work with this backend:
Model:
japan other
---------------- -------------------
GT-6600U Perfection 610
GT-6700U Perfection 640U
GT-7200U Perfection 1250
Perfection 1250 PHOTO
GT-7300U Perfection 1260
Perfection 1260 PHOTO
GT-7600S Perfection 1200S
GT-7600U Perfection 1200U
GT-7600UF Perfection 1200U PHOTO
GT-7700U Perfection 1240U
GT-8300UF Perfection 1660 PHOTO
GT-8700 Perfection 1640SU
GT-8700F Perfection 1640SU PHOTO
GT-8200U Perfection 1650
GT-8200UF Perfection 1650 PHOTO
GT-9300UF Perfection 2400 PHOTO
GT-9400 Perfection 3170 PHOTO
GT-9700F Perfection 2450 PHOTO
GT-9800F Perfection 3200 PHOTO
GT-F500 Perfection 2480 PHOTO
GT-F520 Perfection 3490 PHOTO
GT-F550 Perfection 2580 PHOTO
GT-F570 Perfection 3590 PHOTO
GT-F600 Perfection 4180 PHOTO
GT-F650 Perfection V100 PHOTO
GT-F670 Perfection V200 PHOTO
GT-F700 Perfection V350 PHOTO
GT-S600 Perfection V10
GT-X700 Perfection 4870 PHOTO
GT-X750 Perfection 4490 PHOTO
GT-X770 Perfection V500 PHOTO
GT-X800 Perfection 4990 PHOTO
GT-X900 Perfection V700/V750
ES-2000 Expression 1600
ES-2200 Expression 1680
ES-6000 GT-10000
ES-6000H GT-10000+
ES-6000HS
ES-7000H GT-15000
ES-8500 Expression 1640XL
ES-9000H GT-30000
ES-10000G Expression 10000XL
ES-H300 GT-2500
Stylus CX2800/CX2900/ME200
PX-A550 Stylus CX3500/CX3600
Stylus CX3700/CX3800/DX3800
PX-A620 Stylus CX3900/DX4000
Stylus CX4100/CX4200/DX4200
Stylus CX4300/CX4400/CX5500/CX5600/DX4400
Stylus CX4500/CX4600
PX-A650 Stylus CX4700/CX4800/DX4800
Stylus CX4900/CX5000/DX5000
CC-600PX Stylus CX5100/CX5200
Stylus CX5300/CX5400
PX-A720 Stylus CX5900/CX6000/DX6000
Stylus CX6300/CX6400
Stylus CX6500/CX6600
PX-A640 Stylus CX7300/CX7400/DX7400
Stylus CX7700/CX7800
PX-A740 Stylus CX8300/CX8400/DX8400
PX-FA700 Stylus CX9300F/CX9400Fax/DX9400F
PM-A700 Stylus Photo RX420/RX425/RX430
Stylus Photo RX500/RX510
PM-A750 Stylus Photo RX520/RX530
PM-A820 Stylus Photo RX560/RX580/RX590
PM-A840 Stylus Photo RX585/RX595/RX610
PM-A850 Stylus Photo RX600
PM-A870 Stylus Photo RX620/RX630
PM-A890 Stylus Photo RX640/RX650
PM-A940 Stylus Photo RX680/RX685/RX690
PM-A900 Stylus Photo RX700
PM-A920
PM-A950
PM-A970
PM-T960
PM-T990
LP-A500 AcuLaser CX11
AcuLaser CX21
LP-M5500
LP-M5600
For other scanners the software may or may not work. Please send mail
to sane-devel@lists.alioth.debian.org to report successes or failures.
OPTIONS
The options the backend supports can either be selected through command
line options to programs like scanimage or through GUI elements in
xscanimage or xsane.
Valid command line options and their syntax can be listed by using
scanimage --help -d epkowa
Not all devices support all options.
Scan Mode
The --mode switch selects the basic mode of operation of the
scanner valid choices are Binary, Gray and Color. The Binary
mode is black and white only, Gray will produce up to 256 levels
of gray and Color means 24 bit color mode. Some scanners will
internally use 36 bit color, the external interface however does
only support 24 bits.
The --dropout option determines which color filters are used to
scan in Binary mode. Valid choices are None, Red, Green and
Blue.
The --halftoning switch selects the mode that is used in Binary
mode. Valid options are None, Halftone A (Hard Tone), Halftone B
(Soft Tone), Halftone C (Net Screen), Dither A (4x4 Bayer),
Dither B (4x4 Spiral), Dither C (4x4 Net Screen), Dither D (8x4
Net Screen), Text Enhanced Technology, Download pattern A, and
Download pattern B.
The --dropout switch selects the so called dropout color. Vald
options are None, Red, Green and Blue. The default is None. The
dropout color is used for monochrome scanning and selects the
color that is not scanned. This can be used to e.g. scan an
original with a colored background.
The --brightness switch controls the brightness of the scan.
Valid options are the numbers from -3 to 3. The default is 0.
The larger the brightness value, the brighter the image gets. If
a user defined table for the gamma correction is selected, the
brightness parameter is not available.
The --sharpness switch sets the sharpness of the image data.
Valid options are the numbers from -2 to 2, with -2 meaning
"Defocus", -1 "Defocus slightly", 0 "Normal", 1 "Sharpen
slighly" and 2 "Sharpen".
The --gamma-correction switch controls the scanne internal gamma
correction. Valid options are "Default", "User defined", "High
density printing" "Low density printing" and "High contrast
printing".
The --color-correction switch controls the scanner internal
color correction function. Valid options are "No Correction",
"Impact-dot printers", "Thermal printers", "Ink-jet printers"
and "CRT monitors". The default is "CRT monitors".
The --resolution switch selects the resolution for a scan. Many
EPSON scanners will scan in any resulution between the lowest
and highest possible value. The list reported by the scanner can
be displayed using the "--help -d epkowa" parameters to scanim‐
age.
The --mirror option controls the way the image is scanned. By
reading the image data from right to left the image is mirored.
Valid options are "yes" and "no". The default is "no".
The --speed option can improve the scan speed in monochrome
mode. Valid options are "yes" or "no", the "yes" option will
speed up the scan if this option is supported.
The --auto-area-segmentation switch turns on the automatic area
segmentation for monochrome scans. The scanner will try to
determine which areas are text and which contain images. The
image areas will be halftoned, and the text will be impoved.
Valid options are "yes" and "no". The default is "yes".
The --gamma-table parameter can be used to download a user
defined gamma table. The options takes 256 values from the range
0-255. In color mode this option equally affects the red, green,
and blue channel.
The --red-gamma-table parameter can be used to download a user
defined gamma table for the red channel. The valid options are
the same as for --gamma-table.
The --green-gamma-table parameter can be used to download a user
defined gamma table for the green channel. The valid options are
the same as for --gamma-table.
The --blue-gamma-table parameter can be used to download a user
defined gamma table for the blue channel. The valid options are
the same as for --gamma-table.
The color correction coefficients --cct-1--cct-2--cct-3 ...
--cct-9 will install color correction coefficients for the user
defined color correction. Possible values are in the range
-127..127.
The --preview option requests a preview scan. The frontend soft‐
ware automatically selects a low resolution. Valid options are
"yes" and "no". The default is "no".
The --preview-speed options will increase the scan speed if this
is supported by the scanner. Valid options are "yes" and "no",
the default is "no".
The geometry options -l -t -x -y control the scan area: -l sets
the top left x coordinate, -t the top left y coordinate, -x
selects the width and -y the height of the scan aea. All parame‐
ters are specified in milimeters.
The --quick-format option lets the user select a scan area with
predefined sizes. Valid parameters are "CD", "A5 portrait", "A5
landscape", "Letter", "A4" and "max". The default is "max",
which selects the largest possible area.
The --source option selects the scan source. Valid options
depend on the installed options. The default is "Flatbed".
The --auto-eject option will eject a page after scanning from
the document feeder.
CONFIGURATION FILE
The configuration file /usr/local/etc/sane.d/epkowa.conf specifies the
device(s) that the backend will use. The current version only supports
one scanner per EPSON backend. Possible connection types are:
SCSI This is the default, and if nothing else is specified the back‐
end software will open a given patch as SCSI device. More infor‐
mation about valid syntax for SCSI devices can be found in sane-
scsi(5).
PIP - Parallel Interface
The parallel interface can be configured in two ways: An integer
number starting at the beginning of a line will be interpreted
as the IO address of the parallel port. To make it clearer that
a configured IO address is a parallel port the port address can
be preceded by the string "PIO". The PIO connection does not use
a special device file in the /dev directory.
USB A device file that is preceded by the string "USB" is treated as
a scanner connected via the Universal Serial Bus. The correct
special device file has to be created prior to using it with
Sane. See the USB documentation for more information about how
to set up the USB subsystem and the required device files.
FILES
/usr/local/lib/sane/libsane-epkowa.a
The static library implementing this backend.
/usr/local/lib/sane/libsane-epkowa.so
The shared library implementing this backend (present on systems
that support dynamic loading).
ENVIRONMENT
SANE_DEBUG_EPKOWA
If the library was compiled with debug support enabled, this
environment variable controls the debug level for this backend.
E.g., a value of 128 requests all debug output to be printed.
Smaller levels reduce verbosity.
SANE_EPSON_CMD_LVL
This allows to override the function or command level that the
backend uses to communicate with the scanner. The function level
a scanner supports is determined during the initialization of
the device. If the backend does not recognize the function level
reported by the scanner it will default to function level B5.
Valid function levels are A1, A2, B1, B2, B3, B4, B5, B6, B7, B8
and F5. Use this feature only if you know what you are doing!
SEE ALSOsane-scsi(5), scanimage(1), xscanimage(1), xsane(1), sane-epson(5)BUGS
When used with "scanimage -T" the backend hangs after sucessfully com‐
pleting the tests. It is necessary to powercycle the scanner to get the
communication between backend and scanner going again.
Sometimes the scanner is not initialized correctly. The problem can be
resolved by killing the program and restarting it again.
UNSUPPORTED DEVICES
The backend may be used with EPSON scanners that are not yet listed
under the list of supported devices. A scanner that is not recognized
may default to the function level B3, which means that not all func‐
tions that the scanner may be capable of are accessible.
If the scanner is not even recognized as an EPSON scanner it is proba‐
bly because the device name eported by the scanner is not in the cor‐
rect format. Please send this information to the backend maintainer
(email address is in the AUTHORS file).devices. A scanner that is not
recognized may default to the function level B3, which means that not
all functions that the scanner may be capable of are accessible.
If the scanner is not even recognized as an EPSON scanner it is proba‐
bly because the device name eported by the scanner is not in the cor‐
rect format. Please send this information to the backend maintainer
(email address is in the AUTHORS file).
AUTHOR