NAME
       x10rfxsensors - RFXSensor support for HEYU

DESCRIPTION
       Heyu  is	 an X10 Automation program for Linux, Unix, and Mac OS X.  See
       man page heyu(1) for usage information.

       RFXSensors are remote RF sensors which  transmit	 encoded  Temperature,
       Relative Humidity, and/or Barometric Pressure information, depending on
       configuration.  When equipped with a compatible RF receiver,  Heyu  can
       receive	and  decode  this  information.	 An  overview of these sensors
       appears further down in this page.

SYSTEM REQUIREMENTS
       To use RFXSensors with Heyu requires a W800RF32A/AE or an RFXCOM X10 RF
       receiver with a carrier frequency matching that of the RFXSensor trans‐
       mitter and Heyu version 2.2 or greater.

COMPILER OPTION
       Support for RFXSensors is compiled into Heyu by	default.   A  compiler
       option can be used to omit this support.	 See the file INSTALL included
       in the Heyu distribution source directory for details.

CONFIGURATION
       Start Heyu, including the Heyu Auxilliary  daemon.  Then	 open  another
       xterm window and start the Heyu Monitor.

       The  following examples use RFXSensor data for a system comprised of an
       RFXSensor transmitter with a Relative Humidity sensor plus a  connected
       external Temperature/Barometric Pressure sensor.

       Press  the recessed reset button on the RFXSensor transmitter and some‐
       thing like the following should	appear	in  the	 Heyu  Monitor	window
       (ignoring the dates and times):

	 rcva RFXSensorXmitter	: Type 3, version 10, sample_mode fast
	 rcva RFXSensorInit	: ID 0x00, chip DS2438, serial_no 8755651
	 rcva RFXSensorInit	: ID 0x04, chip DS2438, serial_no 8107391
	 rcva func	 RFdata : Type RFXSensor ID 0x00* Data 0x1429
	 rcva func	 RFdata : Type RFXSensor ID 0x02  Data 0x3AC3
	 rcva func	 RFdata : Type RFXSensor ID 0x01  Data 0x3047
	 rcva func	 RFdata : Type RFXSensor ID 0x04* Data 0x146D
	 rcva func	 RFdata : Type RFXSensor ID 0x06  Data 0x3ACB
	 rcva func	 RFdata : Type RFXSensor ID 0x05  Data 0x1768

       Note:  The  "RFXSensorInit"  messages  will  not	 appear	 when  using a
       W800RF32A/AE receiver or an RFXCOM receiver in 32-bit mode.   They  are
       garbled	with  these  receivers	and  appear to Heyu as RF noise. (Heyu
       doesn't need this data.)

       The asterisk (*) adjoining the IDs 0x00 and 0x04 in the RFdata  entries
       identifies  them	 as the base addresses of the transmitter and external
       sensor.	The RFXSensorInit provides the same information.  If you  have
       more than one RFXSensor transmitter, repeat the above with each to ver‐
       ify that the base addresses for all sensors are unique.

       Now map each transmitter and  each  external  sensor  to	 an  otherwise
       unused  housecode|unit  X10  address  with ALIAS directives in the Heyu
       configuration file using module type RFXSENSOR, e.g.,

	 ALIAS	House	  L9  RFXSENSOR 0x00 TH
	 ALIAS	Basement  C7  RFXSENSOR 0x04 TB

       where the format for this directive is:
	 ALIAS	<label> <hcode|unit> RFXSENSOR <base_addr> <sensor_type>

       <sensor_type> is one of the following:
	 TH for a Temperature and Humidity sensor
	 TB for a Temperature and Barometric Pressure sensor
	 TV for a Temperature and A/D Voltage sensor
	 TP for a Temperature and Potentiometer sensor
	 TT for a Dual Temperature sensor
	 T  for a Temperature-only sensor (1-Wire DS18B20 chip)

       Run ´heyu restart´ to incorporate the  configuration  file  changes  in
       Heyu's  processes,  then again press the reset button on each transmit‐
       ter.  The display in the Heyu Monitor window should now look like this:

	 rcva RFXSensorXmitter	: Type 3, version 10, sample_mode fast
	 rcva RFXSensorInit	: ID 0x00, chip DS2438, serial_no 8755651
	 rcva RFXSensorInit	: ID 0x04, chip DS2438, serial_no 8107391
	 rcva func	rfxTemp : hc L unit 9 Temp 20.125C (House)
	 rcva func	  rfxVs : hc L unit 9 Vs 4.70V (House)
	 rcva func	  rfxRH : hc L unit 9 RH 105.48% (House)
	 rcva func	rfxTemp : hc C unit 7 Temp 20.375C (Basement)
	 rcva func	  rfxVs : hc C unit 7 Vs 4.70V (Basement)
	 rcva func	  rfxBP : hc C unit 7 BP 547.6 hPa (Basement)

       where the functions displayed are  Temperature,	Supply	voltage	 (Vs),
       Relative Humidity (RH), and Barometric Pressure (BP).

       An RFXSensor rfxTemp temperature message will be displayed whenever the
       sampled temperature changes by an amount determined by the 1-Wire  chip
       (as  described  in the RFXSensor data sheet).  The rfxVs supply voltage
       message (and low battery signal, if any) appears only at reset  and  at
       the "heartbeat" intervals (40 or 80 minutes).

UNIT SCALING
       The  native units for output of RFXSensors are Celsius for temperature,
       hPa (hectoPascals) for Barometric Pressure, and Volts for A/D  Voltage.
       These  may be scaled by Heyu to different units with the following con‐
       figuration file directives:

       Directive RFX_TSCALE  <temp_scale>

       where <temp_scale> is F[ahrenheit], C[elsius], K[elvin], or R[ankine].
       Example:
	 RFX_TSCALE  F

       Directive RFX_BPSCALE <BP_unit> <scale_factor> [<offset>]

       where <BP_unit> is the name of the new unit, e.g. mmHg, and <scale_fac‐
       tor>  is	 the  number  by  which the BP in hPa is multiplied to get its
       value in the new unit.
       Some examples:
	 RFX_BPSCALE mmHg 0.75006158
	 RFX_BPSCALE inHg 0.029529983 1.06
	 RFX_BPSCALE millibars 1.0

       The optional <offset> parameter is added to the BP after scaling.

       In the USA at least, barometric	pressures  reported  by	 the  National
       Weather Service are adjusted to the BP at sea level.  The offset can be
       used to approximate this adjustment for altitude.  Typical  values  for
       BP versus altitude can be found on the Internet.

       Directive RFX_VADSCALE <Vad_unit> <scale_factor>

       where <Vad_unit> is the name of the new unit, e.g., mV, and <scale_fac‐
       tor> is the number by which the A/D Voltage is  multipled  to  get  its
       value in the new unit.
       Example:
	 RFX_VADSCALE  mV  1000.0

STORED RFXSENSOR DATA
       If  the Heyu Engine daemon is running, current RFXSensor data is stored
       in the Heyu state tables and displayed in the Heyu log  file  (if  thus
       configured).

       Stored  data  can  be retrieved with the following Heyu state commands.
       Scaled values are displayed for rfxtemp, rfxbp, rfxvad,	and  rfxtemp2.
       The  others  are not scaled.  Hu is the Housecode|Unit address to which
       the sensor has been mapped in the ALIAS directive.
	 heyu rfxtemp  Hu    - Temperature
	 heyu rfxtemp2 Hu    - Second Temperature
	 heyu rfxrh    Hu    - Relative Humidity
	 heyu rfxbp    Hu    - Barometric Pressure
	 heyu rfxvad   Hu    - A/D Voltage
	 heyu rfxpot   Hu    - Potentiometer setting
	 heyu rfxvs    Hu    - Supply Voltage
	 heyu rfxvadi  Hu    - Internal A/D Voltage (unscaled)
	 heyu rfxlobat Hu    - Low Battery indicator (Boolean).

       Note that computation of barometric pressure requires the supply	 volt‐
       age.   Computation of relative humidity requires the supply voltage and
       temperature.  If for whatever reason all the required  quantities  have
       not  yet been stored in the state tables, e.g., after 'heyu initstate',
       the value displayed will be "----" or "Not Ready".

       Also note that rfxlobat (low battery) is a separate function and not  a
       flag as it is with X10 security sensors.

       The  command  ´heyu  show rfxsensors´ will display stored data from all
       configured RFXSensors in tabular form.

HEYU SCRIPTS
       Heyu scripts can be launched by the functions  rfxtemp,	rfxrh,	rfxbp,
       rfxpot, rfxvad, rfxlobat, and rfxtemp2 the same as any other Heyu func‐
       tion.  The source keyword "RCVA" must be included in the launch	condi‐
       tions.
       Example:
	 SCRIPT	 L9 rfxtemp rcva :: my_rfxtemp.sh

SCRIPT ENVIRONMENT
       Any Heyu script has access to the stored RFXSensor values through envi‐
       ronment variables linked to  the	 housecode|unit	 (Hu)  and  its	 alias
       mapped to each RFXSensor.
	 X10_Hu_Temp   x10_<Hu_alias>_Temp
	 X10_Hu_Temp2  x10_<Hu_alias>_Temp2
	 X10_Hu_RH     x10_<Hu_alias>_RH
	 X10_Hu_BP     x10_<Hu_alias>_BP
	 X10_Hu_Pot    x10_<Hu_alias>_Pot
	 X10_Hu_Vad    x10_<Hu_alias>_Vad
	 X10_Hu_Vadi   x10_<Hu_alias>_Vadi
	 X10_Hu_Vs     x10_<Hu_alias>_Vs
	 X10_Hu_LoBat  x10_<Hu_alias>_LoBat  (Boolean)

       No variable is created for data which is invalid or "not ready".

CONFIGURATION DIRECTIVES
       In  addition  to	 the ALIAS and scaling directives mentioned above, the
       following will also affect RFXSensor data.  See man page x10config(5).

       Directive HIDE_UNCHANGED YES|NO

RFXSENSOR OVERVIEW
       RFXSensors are manufactured by RFXCOM (http://www.rfxcom.com) They con‐
       sist of an RF transmitter to which may be optionally connected external
       sensors.	 Models are available which transmit at a frequency of 310 MHz
       for use in North America and at a frequency of 433.92 MHz for use else‐
       where in the world.  The RF signals can be received by  a  W800RF32A/AE
       or RFXCOM X10 RF receiver employing the same carrier frequency.

       RFXSensor  RF  transmitters  have  a built-in 1-Wire temperature sensor
       chip.  The current model ("Type 3") transmitter includes	 an  A/D  con‐
       verter and may optionally include a Relative Humidity (RH) sensor chip.
       The analog output of the RH sensor chip is  encoded  by	the  A/D  con‐
       verter.

       The  RFXSensor  External Sensor modules have a built-in 1-Wire tempera‐
       ture sensor chip, optionally an A/D converter, and optionally either  a
       Relative Humidity (RH) sensor chip or a Barometric Pressure (BP) sensor
       chip.  The analog output of the RH or BP chip is	 encoded  by  the  A/D
       converter.

       In the absence of a RH or BP chip, the A/D converter in a tranmitter or
       external sensor can encode the analog voltage (0 to 10VDC) from a user-
       supplied	 electrical  device,  or  the relative setting of a 10K linear
       potentiometer.

       A total of 64 RFXSensor modules are supported, which may include up to:
	 8 RFXSensor Type 3 RF Transmitters, each with up to 7 RFXSensor
	 External Sensor modules connected in a daisy chain configuration.
	    - or -
	 32 RFXSensor Type 1 or 2 RF Transmitters (both now discontinued),
	 each with a single connected RFXSensor External Sensor module.

       RF signals from RFXSensors include  an  address	which  identifies  the
       transmitter  or	external sensor, and type of signal.  Each transmitter
       has a "base address" which is user configurable (per the RFXSensor data
       sheet) and which must be different for each transmitter.	 Type 3 trans‐
       mitters have a base address which is 0x00 or a multiple of 0x20.	  Type
       1  or 2 transmitters have a base address which is 0x00 or a multiple of
       0x08.  External sensors have a base address assigned by the transmitter
       which is the base address of the transmitter plus a multiple of 0x04.

       When  delivered from the factory, transmitters will usually have a base
       address of 0x00 although this is not guaranteed.

       Note that for a Type 3 transmitter with more than one connected	exter‐
       nal  sensor,  there  is	no  definitive	relationship  between the base
       address assigned to a particular external sensor and  its  position  in
       the daisy chain.	 Furthermore, adding an additional external sensor may
       change the addresses previously assigned to other sensors in the chain.
       Some  experimentation  by  the user may be necessary to determine which
       address is assigned to which external sensor if it's not	 obvious  from
       the temperature readings.

       Each  1-Wire  chip  encodes a unique serial number which is included in
       the power-up and reset message transmission, and which can be  received
       by  an  RFXCOM  X10 receiver operating in variable-length message mode.
       It may come in handy to record this serial  number  somewhere,  perhaps
       even on a label affixed to the sensor.

       Temperature  signals  are transmitted at the base address.  For sensors
       with an A/D converter, the A/D voltage signal  is  transmitted  at  the
       base  address  plus  1  and a Supply voltage signal at the base address
       plus 2.	Software, Heyu in this case, uses the address  as  an  ID  and
       decodes	the  A/D voltage signal according to the kind of sensor, i.e.,
       whether humidity or barometric pressure	or  potentiometer  setting  or
       just as a voltage.

AUTHORS
       RFXSensor support was added to Heyu by Charles W. Sullivan

SEE ALSO
       http://www.rfxcom.com/sensors
       http://www.rfxcom.com/documents/RFXSensor.pdf
       http://www.heyu.org
       heyu(1),	   x10config(5),    x10sched(5),   x10scripts(5),   x10aux(5),
       x10cm17a(5), x10rfxmeters(5)

				     local		      X10RFXSENSORS(5)
[top]

List of man pages available for DragonFly

Copyright (c) for man pages and the logo by the respective OS vendor.

For those who want to learn more, the polarhome community provides shell access and support.

[legal] [privacy] [GNU] [policy] [cookies] [netiquette] [sponsors] [FAQ]
Tweet
Polarhome, production since 1999.
Member of Polarhome portal.
Based on Fawad Halim's script.
....................................................................
Vote for polarhome
Free Shell Accounts :: the biggest list on the net